2024 AART REGISTRY REAL EXAM WITH 300

EXAM ELABORATIONS Aug 28, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

1

2024 AART REGISTRY REAL EXAM WITH 300

QUESTIONS AND CORRECT ANSWERS (100%

CORRECT VERIFIED ANSWERS)/ ARRT - AMERICAN

REGISTRY OF RADIOLOGIC TECHNO LOGISTS REAL

LATEST EXAM 2024 (NEW!!)

The most common cause of x-ray tube failure is

A: a cracked anode

B: a pitted anode

C: vaporized tungsten on glass envelope

D: insufficient heat production - ANSWER-C: vaporized tungsten on glass envelope

If a radiograph were made of an average-size knee using automatic exposure control (AEC) and all three photocells were selected, the resulting radiograph would demonstrate

A: excessive receptor exposure

B: insufficient receptor exposure

C: poor detail

D: adequate exposure - ANSWER-B: insufficient receptor exposure

Which of the following statements regarding SNR is most accurate?

A: SNR increases as mAs increases

B: Low SNR is desirable

C: Low SNR improves resolution

D: SNR increases as kV decreases - ANSWER-A: SNR increases as mAs increases

  • / 4

2

In which of the following examinations would an IR front with very low absorption properties be especially desirable?

A: Extremity radiography

B: Abdominal radiography

C: Mammography

D: Angiography - ANSWER-C: Mammography

The regular measurement and evaluation of radiographic equipment components and their performance is most accurately termed as

A: postprocessing

B: quality assurance

C: quality control

D: quality congruence - ANSWER-C: quality control

A radiograph of a C-spine can be improved by

A: The MSP should be 45* to the plane of the IR

B: The MSP should be 90* to the plane of the IR

C: The chin should be elevated slightly

D: The head should be flexed slightly - ANSWER-C: The chin should be elevated slightly

Which of the following cell types is the LEAST radiosensitive?

A: Myelocytes

B: Myocytes

C: Megakaryocytes

D: Erythroblasts - ANSWER-B: Myocytes 2 / 4

3

Characteristic(s) of a 16:1 grid include

1. it absorbs more useful radiation than an 8:1 grid

2. it has more centering latitude than an 8:1 grid

3. it is used with higher kilovoltage exposures than an 8:1 grid

A: 1 only

B: 1 & 3 only

C: 2 & 3 only

D: 1, 2, & 3 - ANSWER-B: 1 & 3 only

1. it absorbs more useful radiation than an 8:1 grid

2. it has more centering latitude than an 8:1 grid

An exposure was made at 40-inch SID using 5 mAs and 105 kVp, using an 8:1

grid. Another image of the same part is made using a 12:1 grid and 90 kV. Which

of the following exposure times will be MOST APPROPRIATE, using 400 mA, to maintain the original receptor exposure?

A: 0.01 s

B: 0.03 s

C: 0.1 s

D: 0.3 s - ANSWER-B: 0.03 s

All the following statements regarding three-phase current are true, EXCEPT

A: three-phase current is constant-potential direct current

B: three-phase equipment produces more x-rays per milliampere second than

single-phase equipment 3 / 4

4

C: three-phase equipment produces higher average-energy x-rays than single-phase equipment

D: the three-phase waveform has less ripple than the single-phase waveform -

ANSWER-A: three-phase current is constant-potential direct current

The pyloric canal and duodenal bulb are BEST demonstrated during an upper GI series in which of the following positions?

A: RAO

B: Left lateral

C: Recumbent PA

D: Recumbent AP - ANSWER-A: RAO

What is the anatomic structure (#3) that sticks out the sides of a vertebra is

A: Spinous process

B: Transverse process

C: Pedicle

D: Intervertebral foramen - ANSWER-B: Transverse process

With the patient positioned on their stomach with the knee bent at a 40-45* angle, how should the CR be directed to BEST demonstrate the intercondyloid fossa?

A: Perpendicular to the popliteal depression

B: 40* caudad to the popliteal depression

C: Perpendicular to the long axis of the femur

D: 40* cephalad to the popliteal depression - ANSWER-B: 40* caudad to the popliteal depression

Which acronym is used to help rescuers remember the correct CPR step sequence?

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 28, 2025
Description:

2024 AART REGISTRY REAL EXAM WITH 300 QUESTIONS AND CORRECT ANSWERS (100% CORRECT VERIFIED ANSWERS)/ ARRT - AMERICAN REGISTRY OF RADIOLOGIC TECHNO LOGISTS REAL LATEST EXAM 2024 (NEW!!) The most com...

Get this document $30.00