2024 ABRET Final Test

EXAM ELABORATIONS Aug 30, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

2024 ABRET Final Test Actual Questions and Answers 100% Correct

  • What type of montage is shown in this sample?

Answer: Referential Montage

  • Which montage would best display the amplitude of a left temporal spike?-

Answer: Left temporal to the contralateral ear

  • Referential recording is most appropriate for measuring?

Answer: Voltage

  • How can a defective electrode be identified?

Answer: Placing a bad electrode with high impedance into a pin position with

working non reference electrode will result high impedance

  • To confirm the integrity of a poorly recording electrode, the tech should...?
  • Answer: - Replace the electrode with a low impedance in the connection of the poorly recording electrode and recheck impedance

  • 14- and -6/sec Hz positive spikes are best demonstrated with a reference to?

Answer: Contralateral ear reference

  • When using the average reference, if a spike-and-wave focus appears at C3, the
  • abnormality would be best enhanced by?

Answer: Excluding C3 and surrounding electrodes from reference

  • A patient with suspected asymmetrical low-voltage fast activity is observed to
  • have a sweat artifact during the EEG recording. Which of the following EEG settings could be used to reduce the effects of the artifact?

Answer: S= 5 micro- volts/mm, LFF=5 Hz, HFF = 70 Hz

  • In a referential montage localization is determined by?

Answer: Amplitude

  • Switching an effective electrode located in a bad pin position and a good
  • electrode located in working pin position will result in..?Answer: Bad electrode-high impedance in a good pin position; good electrode- high impedance in bad pin position

  • / 2
  • A defective headbox pin can be identified by...?
  • Answer: Placing a non reference electrode with low impedance into a bad pin will result low impedance

  • Increasing the number of seconds displayed on the monitor
  • Answer: Does not change spike amplitude or duration - it shrinks the picture of the displayed waves

  • Which of the following setting is most sensitive

Answer: 2 µV/mm

  • A waveform of 0.5 Hz can be best enhanced with a filter of

Answer: LFF of 0.3 Hz

  • Which of the following time constants would best display delta activity?

Answer: - 1.0 second

  • Time constant

Answer: Low frequency filter

  • A 0.5 Hz wave is enhanced without affecting a spike by using...?

Answer: a LFF 0.3 Hz

  • Frequency Response Curve

Answer: Filters

  • The 60 Hz notch filter will have the greatest effect on a waveform having a
  • duration of

Answer: 16mm/sec

  • A slow wave focus is best seen with...?

Answer: LFF 0.3 Hz, PPS of 15 mm/sec

  • With high frequency filtering, muscle artifact may become distorted and look
  • like...?

Answer: Beta activity

  • Which combination settings will help enhance a low voltage slow wave that is
  • being masked by muscle activity?Answer: Sensitivity of 5µV; LFF of 0.3 Hz; HFF of 35 Hz

  • / 2

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 30, 2025
Description:

2024 ABRET Final Test Actual Questions and Answers 100% Correct 1. What type of montage is shown in this sample? Answer: Referential Montage 2. Which montage would best display the amplitude of a l...

Get this document $30.00