ABSA 4b 702 Questions with Complete Solutions 100% Verified Correct Answers 2024/2025 Warm Air Heating System Equipment In a warm air heating system the cold air return registers are located

  • in exterior walls
  • in interior locations
  • under windows
  • in floors
  • in ceilings - Correct Answer B
  • The major disadvantage of an electric resistance coil furnace for warm air heating is

  • the high cost of electricity
  • the danger from electric shock
  • the high cost of maintenance
  • the large size of the furnace
  • the location of electrical wiring - Correct Answer A
  • Lowboy furnaces are just over

  • 1.0 m in height
  • 0.8 m in height
  • 1.4 m in height
  • 1.6 m in height
  • 1.2 m in height - Correct Answer E
  • The advantage of having duct furnaces instead of a large central furnace is 1 / 4

  • less initial cost
  • easier installation
  • better control of heat in each zone of the building
  • that they require less space
  • lower maintenance costs - Correct Answer C
  • The power supply for an electric resistance coil furnace is

  • 60 V
  • 120 V
  • 240 V
  • 220 V
  • 480 V - Correct Answer C
  • In a fin-coil heat exchanger the primary source of heat for the exchanger is

  • steam or hot water
  • gas
  • oil
  • solar
  • radiant - Correct Answer A
  • A type of directly fired space heater is

  • a unit heater
  • a floor furnace
  • a wall furnace
  • all of the above
  • none of the above - Correct Answer D
  • High efficiency furnaces and heaters range in annual fuel 2 / 4

utilization efficiency (AFUE) from

  • 94 - 98%
  • 80 - 95%
  • 70 - 75%
  • 60 - 70%
  • 50 - 60% - Correct Answer B
  • In high efficiency furnaces if the temperature of the flue gas drops below 65 degrees C the

  • flue gas will condense
  • water vapour will condense
  • furnace burner will shut down
  • furnace burner will start up
  • furnace vent will close - Correct Answer B
  • In a pulse combination furnace the stated efficiency is

  • 94 - 98%
  • 80 - 95%
  • 70 - 75%
  • 60 - 70%
  • 50 - 60%
  • Warm Air Furnace Components and Maintenance - Correct Answer A Heat exchangers in gas fired furnaces are made of

  • brass
  • copper
  • aluminum
  • steel
  • cast iron - Correct Answer D 3 / 4

Air filters can be divided into two groups

  • mechanical and rotating drum
  • electronic and steam
  • dry and wet
  • steam and rotating drum
  • mechanical and electronic - Correct Answer E
  • Electronic filters will remove

  • all particles from the air
  • fine particles from the air
  • odour producing gases from the air
  • smoke from the air
  • all of the above - Correct Answer B
  • The perimeter loop system of furnace ducting is ideal for a building with

  • no insulation in the walls
  • concrete walls
  • no basement
  • low head room in the basement
  • no cold air returns - Correct Answer C
  • Which of the following is a type of outlet in a warm air heating system?

  • a grill
  • a register
  • a ceiling diffuser
  • a perforated panel
  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Questions & answers
Added: Sep 5, 2025
Description: