ABSA 4b 702 Questions with Complete Solutions 100% Verified Correct Answers 2024/2025 Warm Air Heating System Equipment In a warm air heating system the cold air return registers are located
- in exterior walls
- in interior locations
- under windows
- in floors
- in ceilings - Correct Answer B
- the high cost of electricity
- the danger from electric shock
- the high cost of maintenance
- the large size of the furnace
- the location of electrical wiring - Correct Answer A
- 1.0 m in height
- 0.8 m in height
- 1.4 m in height
- 1.6 m in height
- 1.2 m in height - Correct Answer E
The major disadvantage of an electric resistance coil furnace for warm air heating is
Lowboy furnaces are just over
The advantage of having duct furnaces instead of a large central furnace is 1 / 4
- less initial cost
- easier installation
- better control of heat in each zone of the building
- that they require less space
- lower maintenance costs - Correct Answer C
- 60 V
- 120 V
- 240 V
- 220 V
- 480 V - Correct Answer C
- steam or hot water
- gas
- oil
- solar
- radiant - Correct Answer A
- a unit heater
- a floor furnace
- a wall furnace
- all of the above
- none of the above - Correct Answer D
The power supply for an electric resistance coil furnace is
In a fin-coil heat exchanger the primary source of heat for the exchanger is
A type of directly fired space heater is
High efficiency furnaces and heaters range in annual fuel 2 / 4
utilization efficiency (AFUE) from
- 94 - 98%
- 80 - 95%
- 70 - 75%
- 60 - 70%
- 50 - 60% - Correct Answer B
- flue gas will condense
- water vapour will condense
- furnace burner will shut down
- furnace burner will start up
- furnace vent will close - Correct Answer B
- 94 - 98%
- 80 - 95%
- 70 - 75%
- 60 - 70%
- 50 - 60%
- brass
- copper
- aluminum
- steel
- cast iron - Correct Answer D 3 / 4
In high efficiency furnaces if the temperature of the flue gas drops below 65 degrees C the
In a pulse combination furnace the stated efficiency is
Warm Air Furnace Components and Maintenance - Correct Answer A Heat exchangers in gas fired furnaces are made of
Air filters can be divided into two groups
- mechanical and rotating drum
- electronic and steam
- dry and wet
- steam and rotating drum
- mechanical and electronic - Correct Answer E
- all particles from the air
- fine particles from the air
- odour producing gases from the air
- smoke from the air
- all of the above - Correct Answer B
- no insulation in the walls
- concrete walls
- no basement
- low head room in the basement
- no cold air returns - Correct Answer C
- a grill
- a register
- a ceiling diffuser
- a perforated panel
- / 4
Electronic filters will remove
The perimeter loop system of furnace ducting is ideal for a building with
Which of the following is a type of outlet in a warm air heating system?