ACI CONCRETE FIELD TESTING GRADE I

Study Guides Aug 16, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

  • | P a g e

ACI CONCRETE FIELD TESTING GRADE I

PRACTICE EXAM NEWEST 2025 ACTUAL EXAM

COMPLETE 150 QUESTIONS AND CORRECT

DETAILED ANSWERS (VERIFIED ANSWERS)

|ALREADY GRADED A+

---

  • The sensor of the temperature measuring device shall be
  • submerged a minimum of ___ in. [___ mm] into the freshly

mixed concrete:

ANSWER: 3 in. [75 mm]

  • The temperature measuring device shall have a capacity of
  • measuring temperature of freshly mixed concrete to ± ___

degrees F [± ___ C] throughout a range of ___:

ANSWER: 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to

50 C]

  • The temperature measuring device shall be calibrated ___, or

whenever there is a question of ___:

ANSWER: Annually, accuracy

  • | P a g e
  • The temperature of concrete may be measured in a
  • wheelbarrow. True or False?

ANSWER: T

  • The temperature of concrete may be measured in a wall form.
  • True or False?

ANSWER: T

  • A composite sample of concrete is required even if the only
  • purpose for obtaining the sample is to determine temperature.True or False?

ANSWER: F

  • What must be done to the sample container prior to sampling
  • the concrete?

ANSWER: Dampen (with water)

  • | P a g e
  • What must be done to the concrete surrounding the
  • temperature measuring device after the device is submerged in the fresh concrete?

ANSWER: Gently press the concrete around the temperature

measuring device at the surface of the concrete

  • How long must the temperature measuring device remain in
  • the freshly mixed concrete?

ANSWER: At least 2 minutes but not more than 5 minutes

  • After the temperature of the concrete is read, what is
  • required?

ANSWER: Reporting of temperature

  • The temperature of concrete is reported to the nearest ___

degrees F [___ C]:

ANSWER: 1 degree F [0.5 C]

  • | P a g e
  • According to ASTM C1064, what is one reason to take the
  • temperature of concrete?

ANSWER: Verify conformance to a specified requirement for

temperature of concrete

  • A maximum temperature of freshly mixed concrete is
  • specified in ASTM C1064. True or False?

ANSWER: F

  • The sample of concrete used for temperature determination
  • must be rodded 25 times. True or False?

ANSWER: F

  • Sampling by this method is required when tests are to be

made to determine ___ with specification requirements:

ANSWER: Compliance

  • This method covers sampling from four types of mixers,

which are ___, ___, ___, and ___:

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 16, 2025
Description:

ACI CONCRETE FIELD TESTING GRADE I PRACTICE EXAM NEWEST 2025 ACTUAL EXAM COMPLETE 150 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ --- 1. The sensor of the temperatu...

Get this document $30.00