Radiographic Image Analysis 4th Edition Martensen Test Bank

Chapter 01: Guidelines for Image Analysis

MULTIPLE CHOICE

  • The patient demographic requirements for radiographic images include all of the following
  • except

  • patient and facility identification.
  • time and date.
  • birth date.
  • technologist’s identification.

ANS: D REF: P. 8

  • Which of the following is true about image markers?
  • They are radiopaque.
  • They should be reversed before being placed on the IR.
  • They should be positioned as close to the median plane as possible.
  • They will be magnified if positioned on the imaging table or patient.
  • 1 only
  • 1 and 4 only
  • 2 and 3 only
  • 4 only

ANS: B REF: P. 10

  • What is the marker placeT
  • mE eS ntT foB rA thN eK pS roE jeL cL tioE nR o.fC laO teM ral vertebrae?

  • Laterally on the side being identified
  • Anteriorly, identifying the side positioned closer to the IR
  • Anywhere within exposure field
  • Laterally, identifying the side situated closer to the IR
  • ANS: B REF: P. 10 | Box 1-3

  • What is the marker placement for the projection of PA cranium?
  • Laterally on the side being identified
  • Anteriorly, identifying the side positioned closer to the IR
  • Anywhere within the exposure field
  • Laterally, identifying the side situated closer to the IR
  • ANS: A REF: P. 10 | Box 1-3

  • What is the marker placement for the projection of PA oblique vertebrae?
  • Laterally on the side being identified
  • Anteriorly, identifying the side positioned closer to the IR
  • Anywhere within the exposure field
  • Laterally, identifying the side situated closer to the IR
  • ANS: D REF: P. 10 | Box 1-3

  • What is the marker placement of the projection of lateral hand. 1 / 4
  • Laterally on the side being identified
  • Anteriorly, identifying the side positioned closer to the IR
  • Anywhere within the exposure field
  • Laterally, identifying the side situated closer to the IR
  • ANS: C REF: P. 10 | Box 1-3

  • Which guideline should be used to position the identification (ID) plate?
  • Place the ID plate within the collimated field whenever possible.
  • Position the ID plate toward the direction in which the central ray was angled.
  • Position the ID plate next to the narrowest anatomic structure.

ANS: C REF: P. 12

  • Good collimation practices will do all of the following except
  • decrease the radiation dosage.
  • affect the amount of scatter radiation that reaches the IR.
  • reduce the visibility of recorded details.
  • reduce digital radiography histogram analysis errors.

ANS: C REF: P. 14

  • Elongation occurs in all of the following situations except when the
  • part is off center.
  • central ray is angled with the part.
  • central ray and part are perpendicular but the IR is angled.
  • central ray and IR are perpendicular and the part is angled.

ANS: D REF: PP. 22-23

  • For an open joint space to be obtained, the central ray must be aligned to the joint.
  • perpendicular
  • parallel
  • 5 degrees cephalic for each 4 inches of tissue thickness
  • 5 degrees caudal for each 4 inches of tissue thickness

ANS: B REF: P. 25

  • When the central ray is angled, the structure situated is projected the most.
  • farther away from the IR
  • closer to the IR
  • proximal to the tube
  • distal to the tube

ANS: A REF: P. 21

  • Three images were obtained on the same structure with a computed radiography system.
  • Image 1 was obtained using a 48-inch source–image receptor distance (SID) and a 5-inch object–image receptor distance (OID); image 2 was obtained using a 48-inch SID and a 3-inch OID; and image 3 was obtained with a 48-inch SID, a 3-inch OID, and a larger IR.Which image will demonstrate the sharpest recorded detail?

  • Image 1 2 / 4
  • Image 2
  • Image 3
  • There will be no difference in recorded detail.

ANS: B REF: P. 28

  • Three images were obtained on the same structure with a computed radiography system.
  • Image 1 was obtained using a 48-inch source–image receptor distance (SID) and a 5-inch object–image receptor distance (OID); image 2 was obtained using a 48-inch SID and a 3-inch OID; and image 3 was obtained with a 48-inch SID, a 3-inch OID, and a larger IR.Which image will demonstrate the greatest size distortion?

  • Image 1
  • Image 2
  • Image 3
  • There will be no difference in size distortion.

ANS: A REF: PP. 22-23

  • A small focal spot should be used for each of the following situations except when
  • fine detail demonstration is important.
  • extremities are imaged.
  • the milliamperage setting is above 300.
  • the patient can control motion.

ANS: C REF: P. 29

  • An image demonstrating motion and adequate density was obtained using 100 mA at 0.5
  • seconds. If the time is chTanEgSedTtBoA0N.2K5SseEcLonLdEs,Rw.hCatOmMA should be used to maintain density?

  • 100 mA
  • 200 mA
  • 300 mA
  • 400 mA

ANS: B REF: PP. 30-31

  • Anatomical relationships are affected by
  • varying degrees of patient obliquity and flexion.
  • off centering.
  • geometrical factors of magnification, elongation, and foreshortening.
  • similar structures of shape and size.
  • 1 and 4 only
  • 1, 2, and 4 only
  • 1, 3, and 4 only
  • None of the above

ANS: D REF: PP. 18-19

  • Good collimation practices result in which of the following?
  • Reduces histogram analysis errors
  • Clearly delineates the VOI 3 / 4
  • Improves the visibility of recorded details by reducing the amount of scatter radiation
  • that reaches the IR

  • Decreases the radiation dosage by limiting the amount of scatter from the patient
  • 2 and 3 only
  • 1, 2, and 3 only
  • 1, 2, and 4 only
  • 1, 2, 3, and 4

ANS: B REF: PP. 14-15

  • Minimizing size distortion is accomplished by which of the following?
  • Using the longest feasible SID
  • Using the shortest possible OID
  • Decreasing the angle of the CR
  • Placing the part as close to the IR as possible
  • 2 and 3 only
  • 1, 2, and 3 only
  • 1, 2, and 4 only
  • 1, 2, 3, and 4

ANS: C REF: PP. 22-23

  • Collimation guidelines include all of the following except for
  • chest and abdomen projections, collimate to within 1 inch (2.5 cm) of the patient’s skin
  • line.

  • extremity projections, collimate to within 0.5 inch (1.25 cm) of the skin line of the
  • thickest VOI.

  • chest and abdomen projections, collimate to within 0.50 inch (1.25 cm) of the IR edge.
  • collimating structures within the torso, bring the collimated borders to within 1 inch
  • (2.5 cm) of the VOI.

  • 1 and 3
  • 2 and 4
  • 3 only
  • 4 only
  • ANS: A REF: P. 16 | Box 1-4

  • The medial and lateral femoral condyles are not superimposed on a lateral knee projection.
  • The larger, lateral condyle is 1 inch (2.5 cm) anterior to the medial condyle. The best way to correct this error is to

  • rotate the medial condyle 1 inch (2.5 cm) anteriorly.
  • rotate the medial condyle 0.5 inch (1.25 cm) anteriorly.
  • increase the CR angle to accommodate for the larger condyle.
  • increase the CR angle to magnify the smaller condyle.

ANS: C REF: P. 25

  • When imaging long bones, which of the following is (are) correct statements?
  • Choose a large enough IR so that one or both joints are included on the projection.
  • Extend the collimation field so it extends 1 to 2 inches (2.5 cm to 5 cm) beyond the
  • joints spaces as required.

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 29, 2025
Description:

Radiographic Image Analysis 4th Edition Martensen Test Bank Chapter 01: Guidelines for Image Analysis MULTIPLE CHOICE 1. The patient demographic requirements for radiographic images include all of ...

Get this document $30.00