Radiographic Image Analysis 4th Edition Martensen Test Bank
Chapter 01: Guidelines for Image Analysis
MULTIPLE CHOICE
- The patient demographic requirements for radiographic images include all of the following
- patient and facility identification.
- time and date.
- birth date.
- technologist’s identification.
except
ANS: D REF: P. 8
- Which of the following is true about image markers?
- They are radiopaque.
- They should be reversed before being placed on the IR.
- They should be positioned as close to the median plane as possible.
- They will be magnified if positioned on the imaging table or patient.
- 1 only
- 1 and 4 only
- 2 and 3 only
- 4 only
ANS: B REF: P. 10
- What is the marker placeT
- Laterally on the side being identified
- Anteriorly, identifying the side positioned closer to the IR
- Anywhere within exposure field
- Laterally, identifying the side situated closer to the IR
- What is the marker placement for the projection of PA cranium?
- Laterally on the side being identified
- Anteriorly, identifying the side positioned closer to the IR
- Anywhere within the exposure field
- Laterally, identifying the side situated closer to the IR
- What is the marker placement for the projection of PA oblique vertebrae?
- Laterally on the side being identified
- Anteriorly, identifying the side positioned closer to the IR
- Anywhere within the exposure field
- Laterally, identifying the side situated closer to the IR
- What is the marker placement of the projection of lateral hand. 1 / 4
mE eS ntT foB rA thN eK pS roE jeL cL tioE nR o.fC laO teM ral vertebrae?
ANS: B REF: P. 10 | Box 1-3
ANS: A REF: P. 10 | Box 1-3
ANS: D REF: P. 10 | Box 1-3
- Laterally on the side being identified
- Anteriorly, identifying the side positioned closer to the IR
- Anywhere within the exposure field
- Laterally, identifying the side situated closer to the IR
- Which guideline should be used to position the identification (ID) plate?
- Place the ID plate within the collimated field whenever possible.
- Position the ID plate toward the direction in which the central ray was angled.
- Position the ID plate next to the narrowest anatomic structure.
ANS: C REF: P. 10 | Box 1-3
ANS: C REF: P. 12
- Good collimation practices will do all of the following except
- decrease the radiation dosage.
- affect the amount of scatter radiation that reaches the IR.
- reduce the visibility of recorded details.
- reduce digital radiography histogram analysis errors.
ANS: C REF: P. 14
- Elongation occurs in all of the following situations except when the
- part is off center.
- central ray is angled with the part.
- central ray and part are perpendicular but the IR is angled.
- central ray and IR are perpendicular and the part is angled.
ANS: D REF: PP. 22-23
- For an open joint space to be obtained, the central ray must be aligned to the joint.
- perpendicular
- parallel
- 5 degrees cephalic for each 4 inches of tissue thickness
- 5 degrees caudal for each 4 inches of tissue thickness
ANS: B REF: P. 25
- When the central ray is angled, the structure situated is projected the most.
- farther away from the IR
- closer to the IR
- proximal to the tube
- distal to the tube
ANS: A REF: P. 21
- Three images were obtained on the same structure with a computed radiography system.
- Image 1 2 / 4
Image 1 was obtained using a 48-inch source–image receptor distance (SID) and a 5-inch object–image receptor distance (OID); image 2 was obtained using a 48-inch SID and a 3-inch OID; and image 3 was obtained with a 48-inch SID, a 3-inch OID, and a larger IR.Which image will demonstrate the sharpest recorded detail?
- Image 2
- Image 3
- There will be no difference in recorded detail.
ANS: B REF: P. 28
- Three images were obtained on the same structure with a computed radiography system.
- Image 1
- Image 2
- Image 3
- There will be no difference in size distortion.
Image 1 was obtained using a 48-inch source–image receptor distance (SID) and a 5-inch object–image receptor distance (OID); image 2 was obtained using a 48-inch SID and a 3-inch OID; and image 3 was obtained with a 48-inch SID, a 3-inch OID, and a larger IR.Which image will demonstrate the greatest size distortion?
ANS: A REF: PP. 22-23
- A small focal spot should be used for each of the following situations except when
- fine detail demonstration is important.
- extremities are imaged.
- the milliamperage setting is above 300.
- the patient can control motion.
ANS: C REF: P. 29
- An image demonstrating motion and adequate density was obtained using 100 mA at 0.5
- 100 mA
- 200 mA
- 300 mA
- 400 mA
seconds. If the time is chTanEgSedTtBoA0N.2K5SseEcLonLdEs,Rw.hCatOmMA should be used to maintain density?
ANS: B REF: PP. 30-31
- Anatomical relationships are affected by
- varying degrees of patient obliquity and flexion.
- off centering.
- geometrical factors of magnification, elongation, and foreshortening.
- similar structures of shape and size.
- 1 and 4 only
- 1, 2, and 4 only
- 1, 3, and 4 only
- None of the above
ANS: D REF: PP. 18-19
- Good collimation practices result in which of the following?
- Reduces histogram analysis errors
- Clearly delineates the VOI 3 / 4
- Improves the visibility of recorded details by reducing the amount of scatter radiation
- Decreases the radiation dosage by limiting the amount of scatter from the patient
- 2 and 3 only
- 1, 2, and 3 only
- 1, 2, and 4 only
- 1, 2, 3, and 4
that reaches the IR
ANS: B REF: PP. 14-15
- Minimizing size distortion is accomplished by which of the following?
- Using the longest feasible SID
- Using the shortest possible OID
- Decreasing the angle of the CR
- Placing the part as close to the IR as possible
- 2 and 3 only
- 1, 2, and 3 only
- 1, 2, and 4 only
- 1, 2, 3, and 4
ANS: C REF: PP. 22-23
- Collimation guidelines include all of the following except for
- chest and abdomen projections, collimate to within 1 inch (2.5 cm) of the patient’s skin
- extremity projections, collimate to within 0.5 inch (1.25 cm) of the skin line of the
- chest and abdomen projections, collimate to within 0.50 inch (1.25 cm) of the IR edge.
- collimating structures within the torso, bring the collimated borders to within 1 inch
- 1 and 3
- 2 and 4
- 3 only
- 4 only
line.
thickest VOI.
(2.5 cm) of the VOI.
ANS: A REF: P. 16 | Box 1-4
- The medial and lateral femoral condyles are not superimposed on a lateral knee projection.
- rotate the medial condyle 1 inch (2.5 cm) anteriorly.
- rotate the medial condyle 0.5 inch (1.25 cm) anteriorly.
- increase the CR angle to accommodate for the larger condyle.
- increase the CR angle to magnify the smaller condyle.
The larger, lateral condyle is 1 inch (2.5 cm) anterior to the medial condyle. The best way to correct this error is to
ANS: C REF: P. 25
- When imaging long bones, which of the following is (are) correct statements?
- Choose a large enough IR so that one or both joints are included on the projection.
- Extend the collimation field so it extends 1 to 2 inches (2.5 cm to 5 cm) beyond the
- / 4
joints spaces as required.