The best axial resolution will be apparent if the sonographer performs an exam with a transducer that has which characteristic?

  • Longer pulse length
  • Longer wavelength
  • Shorter pulse length
  • More ringing in the pulse - CORRECT ANSWER -c. Shorter
  • pulse length

Lateral resolution will be improved if the sonographer performs which operation?

  • Decreases the scanning depth
  • Increases the number of focal zones 1 / 4
  • | P a g e
  • Maximizes the output power
  • Uses a lower frequency - CORRECT ANSWER -b. Increases
  • the number of focal zones

Which action will NOT increase (or improve) temporal resolution?

  • Increase the imaging depth.
  • Decrease the number of focal zones.
  • Use a sector size that is narrow.
  • Use a low line density. - CORRECT ANSWER -a. Increase
  • the imaging depth.

Which name describes how the angles of the incident and transmission beams are related to the speed of the two media?

  • Bernoulli's principle
  • Curie point
  • Huygens' principle
  • Snell's law - CORRECT ANSWER -d. Snell's law

What can be done when investigating a possible kidney stone to better 2 / 4

  • | P a g e

demonstrate shadowing from the stone when using a 3 MHz probe?

  • Position the focal point deeper than the stone.
  • Increase the amount of gain.
  • Increase the frequency to 5 MHz.
  • Decrease the output power of the system. - CORRECT
  • ANSWER-c. Increase the frequency to 5 MHz

If the frequency is doubled, what effect will this have on the wavelength?

  • It will remain the same.
  • It doubles.
  • It increases by a factor of 1.54.
  • It is halved. - CORRECT ANSWER -d. It is halved.

Which part of the transducer is necessary to reduce the amount of ringing of the piezoelectric (PZT) crystal?

  • Matching layer
  • Backing material
  • Transducer housing
  • Wire - CORRECT ANSWER -b. Backing material
  • / 4
  • | P a g e

A given frequency of sound is 4.5 MHz, and it has a wavelength of 0.8 mm.How thick should a manufacturer design the matching layer of a transducer in this scenario?

  • 0.4 mm
  • 0.16 mm
  • 0.2 mm
  • 0.6 mm - CORRECT ANSWER -c. 0.2 mm

A sonographer is performing a renal ultrasound. Which transducer frequency will generate the slowest speed of sound?

  • All frequencies will travel at the same speed in the same
  • tissue.

  • 2 MHz
  • 4.5 MHz
  • 7 MHz - CORRECT ANSWER -a. All frequencies will travel
  • at the same speed in the same tissue.

Transducers used in image production will have which characteristics?

  • High Q-factor, wide bandwidth
  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 30, 2025
Description:

ARDMS ACTUAL EXAM NEWEST 2024 COMPLETE 100 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ ||BRAND NEW VERSION!! The best axial resolution will be apparent if the sonog...

Get this document $30.00