Backflow Prevention Practice Exam Latest Update 2024-2025 100 Questions and 100% Verified Correct Answers Guaranteed A+ A backflow preventer creates a closed plumbing system that requires the installation of a(n) _____?

  • Expansion tank
  • Globe valve
  • Pressure reducing valve
  • Temperature and pressure relief valve

E. Utility box key - CORRECT ANSWER: Expansion tank

A barometric loop must be installed 35 ft (10.7 m) above the highest ____?

  • Boiler
  • Fixture outlet
  • Gate valve
  • Service connection

E. Water meter - CORRECT ANSWER: Fixture outlet

A check valve field test reported value of 0.8 psid (5.5 kPa) suggests _____?

  • A passing check valve
  • A broken or failed spring
  • Debris in the check seat
  • Disc softening or decay

E. Low water pressure - CORRECT ANSWER: Disc softening or decay

A common backflow preventer on a double-wall heat exchanger with leak detection is ____?

  • An air-gap separation
  • An atmospheric vacuum breaker
  • A double check valve assembly
  • A reduced pressure principle assembly

E. Nothing - CORRECT ANSWER: Nothing

A cross-connection may be a permanent piping arrangement or a(n) ____?

  • Backflow preventer
  • Church symbol
  • OSHA hazardous area designation
  • Railroad and highway intersection sign

E. Temporary hose bibb connection - CORRECT ANSWER: Temporary hose bibb

connection

A deck-mounted atmospheric vacuum breaker's critical installation level is above the outlet usage by ___?

  • 1 in. (2.5 cm) 1 / 3
  • 3 in. (7.6 cm)
  • 6 in. (15 cm)
  • 12 in. (30 cm)

E. 18 in. (46 cm) - CORRECT ANSWER: 1 in. (2.5 cm)

A differential pressure gauge reading of 0.2 psid is represented on water column sight tube by _____?

  • 1/16 in. (0.16 cm)
  • 1/2 in. (1.3 cm)
  • 2 in. (5.1 cm)
  • 3.5 in. (8.9 cm)

E. 5.5 in. (14 cm) - CORRECT ANSWER: 5.5 in. (14 cm)

A direct cross-connection suggests the piping system may be subjected to ____?

  • Backpressure or backsiphonage
  • Backsiphonage only
  • Periodic inspection
  • Sustained pressure

E. Toxic materials - CORRECT ANSWER: Backpressure or backsiphonage

A double check valve assembly installed in a vertical flow down orientation is only allowed ______?

  • In a basement or vault
  • If the assembly was tested and approved as such
  • If the check weight does not compress the spring
  • On fire-suppression systems

E. On water supply service connections - CORRECT ANSWER: If the assembly was

tested and approved as such

A double check valve assembly is installed 12 in. (30.5 cm) above the floor for _____?

  • Electrical code compliance
  • Floor draining
  • Maintenance
  • Mechanical code compliance

E. Rodent control - CORRECT ANSWER: Maintenance

A field test report for a double check valve assembly will include the manufacturer's name, model, size, and _____?

  • Body material
  • Date of manufacture
  • Serial number
  • Working pressure (maximum)

E. Working temperature (maximum) - CORRECT ANSWER: Serial number

A fire sprinkler system's backflow protection for a black-iron pipe system is typically

____? 2 / 3

  • An air-gap separation
  • A double check valve assembly
  • A reduced pressure principle assembly
  • A reduced pressure detector assembly

E. No protection required - CORRECT ANSWER: A double check valve assembly

A hose connection vacuum breaker's maintenance includes _____?

  • Check disc replacement
  • Diaphragm replacement
  • Draining for winterization
  • Replacement every 2 years

E. Water flushing - CORRECT ANSWER: Draining for winterization

A hose-bibb connection is required to have a permanently installed ____?

  • Atmospheric vacuum breaker
  • Backflow preventer
  • Pressure vacuum breaker
  • Shut-off valve

E. Spill-resistant vacuum breaker - CORRECT ANSWER: Atmospheric vacuum

breaker

A low-hazard use only backflow preventer is a(n) _____?

  • Air-gap separation
  • Atmospheric vacuum breaker
  • Double check valve assembly
  • Pressure vacuum breaker assembly

E. Reduced pressure principle assembly - CORRECT ANSWER: Double check valve

assembly

A pipe restriction's flow velocity increase may allow ____?

  • Aspiration
  • Backpressure
  • Low turbulence
  • Pressure head

E. Pressure surges - CORRECT ANSWER: Aspiration

A pressure vacuum breaker may have ____ on the assembly's discharge piping.

  • Auxiliary water supply looped irrigation
  • A boiler
  • A booster pump
  • Elevated piping

E. Irrigation sprinkler heads - CORRECT ANSWER: Irrigation sprinkler heads

A properly installed barometric loop will prevent _____?

  • Backpressure
  • Backsiphonage
  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 17, 2025
Description:

Backflow Prevention Practice Exam Latest Update 2024-2025 100 Questions and 100% Verified Correct Answers Guaranteed A+ A backflow preventer creates a closed plumbing system that requires the insta...

Get this document $30.00