Baylor Scott & White EKG test Latest Update 2024 Version Questions and Verified Correct Answers Guaranteed Success <40bpm - CORRECT ANSWER: accelerated idioventricular rhythm is anything greater than?
<60bpm - CORRECT ANSWER: junctional rhythm rate is?
1st degree AV block - CORRECT ANSWER: only one with no extra P wave, often
confused with NSR, PR interval is >0.20
2nd degree AV block T1 - CORRECT ANSWER: inconsistent PR interval, R-R
inconsistent
INCONSISTENCY
2nd degree AV block T2 - CORRECT ANSWER: P-R intervals CONSISTENT, more P
waves than QRS, R-R inconsistent
a fib - CORRECT ANSWER: wavy P waves, TX: with HypoTN use cardioversion and anticoagulant
atrial flutter - CORRECT ANSWER: P waves sawtooth, TX: support airway, ditiaziam, bblockers
complete heart block - CORRECT ANSWER: R-R consistent, P-P consistent (EVEN IF
IMAGINARY), P-R inconsistent
failure to capture - CORRECT ANSWER: like if you have a camera that doesnt
capture/produce the product/picture!
failure to sense - CORRECT ANSWER: spike happens in between something
happening
interrupter!
Idioventricular Rhythm - CORRECT ANSWER: no P waves, WIDE QRS, T wave
opposite
junctional rhythm - CORRECT ANSWER: youll see the J, rate 40-60bpm, PR interval
<0.12, P waves inverted! TX: same as bradycardia
NSR (Normal Sinus Rhythm) - CORRECT ANSWER: