  • Types of Hot Work - CORRECT ANSWER: Class II: Minimal energy, localized sparks,
  • DCA or Fire Marshal determines if fire watch is needed

Class I: High energy, lots of sparks, fire watch is required

2190 LO - CORRECT ANSWER: Ueses; MRG, Air Comps, LSB's, CPP's, Steam

Turbines

7 conditions for double barrier protection - CORRECT ANSWER: Hi T - High

Temperature (>200 deg F)

O - Oil (with Flash Point <200 deg F)

P - Penetration below waterline

Hi P - High Pressure (>1000 psi)

  • / 4

O - Oxygen systems

P - Pipe greater than ½ inch

HazMat - Hazardous Material (toxic vapor)

AFFF (Aqueous Film Forming Foam) - CORRECT ANSWER: Size: 28lb

Range: 10ft

Class of Fire: Bravo

Time: 45 to 65 sec

Extinguishing Method: Creates a vapor barior and cools the fire

AFFF Fixed System - CORRECT ANSWER: -Premixed hose lines with 6% solution to

94% water

-Also found in aircraft hangers with sprinkler set-up

-Found in the bilge of engine rooms to put out fuel fires

  • / 4

Aft Steering Safety Officer - CORRECT ANSWER: Officer in Aft Steering during special operations

API/Specific Gravity Test - CORRECT ANSWER: test is the weight of given volume of fuel vs. weight of an equal volume of water at 60°F

Assistant Chief Engineer (ACE) Responsibilities - CORRECT ANSWER: -Acts as the

CHENG's executive agent

-Enforces standards both in maintenance and operations

-Leads the training on the deck plates to ensure the spaces are safe and personnel are not only using proper procedures but understand them

-Not always billeted on small ships. A hard-charging engineering DIVO will fill in this position towards the end of their tour

Audiogram Requirements - CORRECT ANSWER: -Baseline

-Annual

-Termination of Service

Automatic Bus Transfer (ABT) - CORRECT ANSWER: Transfer to alternate feeder when normal feeder voltage drops to 60-70% of normal rated voltage for more than 0.3-0.5 seconds. Transfers back to the normal source when voltage is back to 85-95% of rated voltage. Short time delay.

Auxiliary Officer (AUXO) Responsibilities - CORRECT ANSWER: -Responsible for non- probulsion diesels and aux equipment (Fresh water, sewage, compressed air, A/C, etc.) 3 / 4

-Responsible for small boats

Battle Dress - CORRECT ANSWER: -FRV (Flame resistant variant) coveralls

-All buttons buttoned

-Pant cuffs tucked into boots or socks

-Life preserver worn on the waist (or kept at GQ (General Quarters) station)

-Flash hood and gloves

Battle Organization Underway - CORRECT ANSWER:

Benifity of Casuality Power - CORRECT ANSWER: -Preservation of watertight integrity

-Simplicity of installation and operation

-Flexibility of application

-Interchangeability of parts and equipment

Bottom Sediment & Water Test (BS&W) - CORRECT ANSWER: -Done during recipt of fuel and periodically as needed

-Test for water and sediment content

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 26, 2025
Description:

BDOC 2023 DC-Engineering Review Latest Update 2025-2026 190 Questions and 100% Verified Correct Answers Guaranteed A+ 2 Types of Hot Work - CORRECT ANSWER: Class II: Minimal energy, localized spark...

Get this document $30.00