QUESTIONS WITH 100% CORRECT

ANSWERS | VERIFIED | LATEST

UPDATE | 25 PAGES

Question : What does PSIA stand for?

Correct answer: Psig + atmospheric pressure

Question : Carryover can lead to:

Correct answer: Water Hammer

Question : Water column & gauge glass should be blown

down:

Correct answer: Daily

Question : If water leaves the boiler at 170•, what temperature

does it return at?

Correct answer: 150•

  • | Page

Question : What is the most common cause of cast iron boiler

failure?

Correct answer: Cracking

Question : The positioning control cannot function without:

Correct answer: Air

Question : What is the most common of problems in a hot

water system?

Correct answer: Air

Question : What fire tube is most efficient?

Correct answer: 4 Pass

Question : Where are the combustion gases on a serpentine

boiler?

Correct answer: Below the tubes

Question : What is the purpose of a check valve?

  • | Page

Correct answer: To Prevent reverse flow & Allow flow in one

direction

Question : A solenoid valve:

Correct answer: Is an automatic gas shutoff valve

Question : The most common type of pressure control device

used is the:

Correct answer: Mercury Tube

Question : A steam gauge is calibrated in:

Correct answer: Lbs/Sq. Inch

Question : Heavy soot on the fireside of tubes:

Correct answer: Should be removed for better heat transfer

Question : What code is a heating boiler built to:

Correct answer: ASME Section IV(4)

  • | Page

Question : When connecting a Bourdon tube steam gauge to a

boiler, a pigtail is used to:

Correct answer: Protect Bourdon tube from steam

Question : External feed water treatment can be a _____

process.

Correct answer: Cold lime soda, hot lime soda, or ion

exchange

Question : Natural water may contain:

Correct answer: Solids and other pollutions

Question : What is the min. temp of a hot water boiler

operation to prevent condensation?

Correct answer: 170 F

Question : What test is performed on re-tubed (repaired)

boiler and what is the water temp.?

Correct answer: Hydrostatic test at 70F

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 16, 2025
Description:

BLACK SEAL TEST STUD Y GUIDE | 230 QUESTIONS WITH 100% CORRECT ANSWERS | VERIFIED | LATEST UPDATE | 25 PAGES Question : What does PSIA stand for? Correct answer: Psig + atmospheric pressure Questio...

Get this document $30.00