Bonent Review 270 Questions with Complete Solutions 2023/2024 During pre-treatment patients evaluation what is the best question for the PCT to ask? - Correct Answer How have you been since your last dialysis treatment?During the set- up of a machine the alarm test for conductivity fails. Which action would be best for the pct to take - Correct Answer Contact the biomed equipment tech The dialysis industry strives to improve the quality of patient outcomes. One way this is done is through continuous quality improvement (CQI) process. What is a model of the CQI process? - Correct Answer plan, do, check, and act Nephron - Correct Answer The functional unit of the kidney is called the Diabetes - Correct Answer The number one reason for chronic kidney failure is the united states is?What is the acid-base imbalance commonly seen in patients with chronic renal failure? - Correct Answer Metabolic acidosis What are the functions of the kidney? - Correct Answer Fluid balance Electrolyte balance Elminates metabolic waste Approximately what percent of the cardiac output is received by the kidney's? - Correct Answer 23% What is considered an elevated serum potassium level for a dialysis patient? - Correct Answer 5.5 mEq/L Hormones made by the kidney are? - Correct Answer Erythropoietin Calcitriol Renin Hyperkalemia may cause - Correct Answer Serious or even deadly changes in the heart rhythm What is the PCT's role in patient teaching? - Correct Answer Reinforce teaching the patient may have received from the nurse, physician, dietitian, or other teammates What type of vascular access has fewest complications? - Correct Answer The a/v fistula 1 / 3

Risks associated with a deionization (D.I) water treatment system? - Correct Answer Once a DI system is exhausted it releases all of the ions it once held.DI has caused most of the water treatment related deaths in patients.DI does not remove bacteria The absence of pathogens - Correct Answer Asepsis What organization establishes dialysis water quality standards? - Correct Answer Association for the Advancement of Medical Instrumentation (AAMI) To make public drinking water safe municipal water supplies commonly treat water with chemical additives. These same additives must be removed from the water supply used for hemodialysis. Common drinking water additives are? - Correct Answer Chlorine and Ammonia Fluorine Alum Hemolysis - Correct Answer Bursting of red blood cells Hemodialysis infection control precautions are? - Correct Answer Dispose of needles in a puncture resistant color coded box.Always wear a protective gown where there is potential for contact with blood or body fluids.Promptly clean blood spills/splashes with appropriate disinfecting agent For patient or equipment contact.When troubleshooting the vascular access.Handling blood/body fluid samples. - Correct Answer Gloves must be worn The heparin sodium concentration commonly used in hemodialysis is - Correct Answer 1ml 1,000 units When should the PCT verify the absence of residual sterilant? - Correct Answer Immediately before initiating treatment If the extracorporeal circuit clots, it would be most important to monitor the patients? - Correct Answer Hemoglobin level One reason normal saline is used to prime the extracorporeal circuit prior to initiating treatment is to - Correct Answer Remove air What is the name of the instrument used to measure blood pressure? - Correct Answer Sphygmomanometer What would improve the adequacy of the dialysis treatment - Correct Answer Increase the treatment time 2 / 3

During a hemodialysis treatment a patient goes into cardiac arrest. What should the PCT do first? - Correct Answer Call for help Prior to cannulation the technician notices the patient's a/v fistula is red and warm to the touch. These symptoms are most likely due to - Correct Answer Clotting Lab results indicate the patient's pre-treatment BUN value was lower than the post treatment BUN value. A potential cause could be - Correct Answer The pre-dialysis sample was taken from the venous line after the treatment started Half way through a treatment the technician notices a significant increase in transmembrane pressure. This is most likely due to - Correct Answer Clotting of the dialyzer A technician notices a drop of blood on the surface of a patient's hemodialysis machine.The best action is to - Correct Answer Clean the machine surface immediately When the technician accidentally spills undiluted bleach on the floor which resource will provide the PCT with the appropriate safety information and guidance on how to clean the spill? - Correct Answer The MSDS Osmosis - Correct Answer The movement of fluid from an area of low solute concentration to an area of high solute concentration What is the most accurate measure of dialysis adequacy? - Correct Answer KT/V Diffusion - Correct Answer Solutes from an area of high concentration to an area of low concentration Pericarditis is a complication seen in renal failure patients - Correct Answer Inadequate dialysis prescription.Missed dialysis treatments.Fluid overload Peripheral neuropathy - Correct Answer Tingling or numbness in the toes and fingers What physician orders may be expected for a patient with pericarditis? - Correct Answer Increased dialysis time.No heparin dialysis Biohazardous waste includes any material exposed to - Correct Answer Blood and body fluid.Sharps and infectious waste.Pathology specimens and infectious mircobiological materials.

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Questions & answers
Added: Sep 5, 2025
Description:

Bonent Review 270 Questions with Complete Solutions During pre-treatment patients evaluation what is the best question for the PCT to ask? - Correct Answer How have you been since your last dialysi...

Get this document $30.00