Question 1: Min #receptacles in a garage

Correct answer: 1

Question 2: Mobile home service equipment shall be line of

sight and no more than ____ from the exterior wall of the home

Correct answer: 30'

Question 3: If a service conductor is over 300V but less than

600V, what is the minimum clearance of that service conductor if it runs in residential and commercial areas that are not subject to traffic?

Correct answer: 15'

Question 4: A power meter must be a minimum of ____ feet

away from any door, gas meter, or window opening

Correct answer: 3

Question 5: A rod-type grounding electrode should have a

minimum diameter of

  • | Page

Correct answer: 5/8"

Question 6: Conductors entering buildings shall be protected:

Correct answer: To the point of entrance

Question 7: A grounding electrode must be in contact with soil a

minimum:

Correct answer: 8'

Question 8: If a raceway has various conductors coming from

different systems, then you should group each system separately

every:

Correct answer: 6'

Question 9: What is the maximum distance a service conductor

can run over a roof?

Correct answer: 6'

Question 10: Soldered connections are not permitted for

Correct answer: Grounded connections

  • | Page

Question 11: Refer to diagram. If you have 0 to 150 nominal

voltage to ground, then what is the minimum clear distance required from such equipment?

Correct answer: 3'

Question 12: What color marking is required for conductors or

busbars that carry the higher voltage to ground and these marking are required at connection points that have a grounded conductor present?

Correct answer: Orange

Question 13: What is the purpose of a BOS?

Correct answer: Integrates PV into the building's load

Question 14: Cable trays or similar raceways carrying service

entrance conductors must:

Correct answer: Be Labled

Question 15: Which of the following bulbs cannot be used with

dimmer switches?

  • | Page

Correct answer: All of the listed bulb types can be used with

dimmers provided the dimmer is designed, tested and UL listed for the specific lighting source or load type

Question 16: What is the most common location for trim in

electrical equipment?

Correct answer: Panelboards

Question 17: What is the most common location for terminal

lugs?

Correct answer: Batteries in PV system

Question 18: What is the minimum length of a concrete-encased

grounding electrode?

Correct answer: 20'

Question 19: If a conductor is 600V or less, what is the

minimum height of a service conductor that runs over public roads, alleys, and parking areas subject to traffic?

Correct answer: 18'

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 3, 2025
Description:

California CSLB C10 Electrical Exam | Questions with 100% Correct Answers | Verified | Latest Update Question 1: Min #receptacles in a garage Correct answer: 1 Question 2: Mobile home service equip...

Get this document $30.00