California UST Service Technician part 1 Latest Update 2025-2026 60 Questions and 100% Verified Correct Answers Guaranteed A+

A written statement indicating SIR results must be submitted to the ____every____ -

CORRECT ANSWER: Local agency , 12 months

According to EO VR 101 E maintance records are required to include? - CORRECT

ANSWER: Name and designated UST operator .

According to EO VR 201 A What could cause a nozzle shut off mechanism or

malfunction? - CORRECT ANSWER: Depended filter seal damage

According to EO VR 2010 after installing a new spout assembly in the Healy 900 nozzle

the following test must be conducted ? - CORRECT ANSWER: Nozzle dispensing shut

off test

According to Healy EO VR 201 A a vapor recovery record are to be maintained by? -

CORRECT ANSWER: Gasoline dispensing facility operator

(GDF)

According to PEI RP 300 a combustible gas can be used to ? - CORRECT ANSWER:

Detect vapor leaks in a vapor recovery system.

According to PEI RP 300 as built drawing or pictures of the underground pipping and

other components shall be ? - CORRECT ANSWER: Maintained as long as UST is in

service

  • / 2

According to PEI RP 300 the following method of documenting piping location is NOT to

? - CORRECT ANSWER: Sketch a diagram on the inside cover of vapor recovery

equipment manual

According to PEI RP 300. A written scope of work for vapor recovery installation should

include? - CORRECT ANSWER: Construction plans

According to the health and safety code the owner of a new tank must conduct a one time ELD test if the tank is located within 1000 ft of a public drinking water well. This test

must accomplished by ? - CORRECT ANSWER: January 1, 2005

According to title 23; the following piping components if installed after July 1 1987 must

have secondary containment - CORRECT ANSWER: Pressured product piping

According to VR 201 A Breakaway reconnection must be ? - CORRECT ANSWER:

Logged in GDF log

An approved method for non visual monitoring for existing UST systems. - CORRECT

ANSWER: Statistical Inventory Reconciliation (SIR)

An unauthorized release which does not escape secondary containment, requires only recordation on the Operators Manual Report provided. - CORRECT ANSWER: It did not cause deterioration of secondary containment.It did not increase the hazard of fire.It was cleaned up within eight hours addicti it was cleaned up within eight hours detection.

ATG must be capable for detecting a release of ? - CORRECT ANSWER: .2 gallons per hour

ATG should be programmed to test the tank ? - CORRECT ANSWER: At least monthly

  • / 2

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 27, 2025
Description:

California UST Service Technician part 1 Latest Update 2025-2026 60 Questions and 100% Verified Correct Answers Guaranteed A+ A written statement indicating SIR results must be submitted to the ___...

Get this document $30.00