Automatic Tube Current Modulation - ANSWER-regulates optical density by adjusting mA to the xray tube thus sustaining the same density (area) being scanned.

Angular Modulation - ANSWER-within the scanning field of view, automatic modulation occurs by mA adjustment in the x-y axis

reducing the amount of radiation exposure which is based on the level of attenuation

AEC application - automatic exposure control - ANSWER-variation fo mAs are noted as the optical density varies from the head to neck to chest

the scout film defines the appropriate adjustments

technologist defines the image noise target value which should remain constant throughout the variations in density with the patient's body

Fourier Transform - ANSWER-The projection -slice theorem, which states that the one- dimensional Fourier Transform of the projection of a two-dimensional signal is equal to the slice of its two dimensional at the same angle

Poly-energetic X-ray - ANSWER-produced in a range of keV as the electron beam sticks and strikes the tungston anode

Increasing the voltage (kVp) to the tube - ANSWER-generates greater energized poly- energetic x-ray energy

As kVp increases - ANSWER-K and L characteristic x-rays are produced

Brumsstrahlung - ANSWER-occurs at all levels of kVp

Shielding - ANSWER-The lead housing that surrounds the x-ray tubes because xrays occur in every direction and to absorb secondary xrays

milli-amperes per second (mAs) - ANSWER-the quantity of xrays produced

the greater the current - ANSWER-more xrays produced within a preset kVp

the greater the mAs - ANSWER-the greater the dose to the patient

  • / 2

kVp - ANSWER-applied to increase the xrays penetration

mAs - ANSWER-defines the amount of xrays

Detecting the xrays - ANSWER-Gas Xenon detectors Scintallation detectors

Gas Xenon detectors - ANSWER-Xrays are absorbed with chambers, genreating postive and negative ions, image represents a single row of detectors

X-ray Production - ANSWER-produced by accelerating elec trons with a high voltage and allowing them to collide with the focal spot.

The opening collimates the beam but must first pass through - ANSWER-a layer of aluminum

Aluminum - ANSWER-Filters out low energy x-rays

Computed Tomography - ANSWER-machine that uses xrays, a powerful form of electromagnetic energy

combines x radiation and radiation detectors coupled with a computer to create cross sectional image of any part of the body

Quantum detection efficiency (QDE) is not as efficient as solid state detectors

Scintillation Detection - ANSWER-Similar to a gamma camera, xrays are absorbed by a NaI crystal, scintillation occurs and a PMT converts the light to an electron event

Issue with scintillation detection - ANSWER-dead time (afterglow)

Solid state detector crystals - ANSWER-either cadium tungstate or ceramic rare earth oxide

solid state detectors - ANSWER-silicon based semiconductor has greater absorption based on its density

xrays absorbed causing scintillation where a lens focuses the light

electrons pairs passing from positve to negative side generating a pulse

system contains proportionality

The Transmission Data - ANSWER-as the beam passes through an object it becomes attenuated by the type of object it encounters

  • / 2

Download Document

Buy This Document