HVAC EXCELLENCE Latest Update 2025-2026 Actual Exam 100 Questions with 100% Verified Correct Answers Guaranteed A+ Verified by Professor

- CORRECT ANSWER:

____ can be used for leak detection with ALL high pressure refrigerants - CORRECT

ANSWER: Soap Bubbles

10 lbs of refrigerant passing through a water cooled condenser will lose 20 BTU of heat/ pound. If 10#'s of water passes through the condenser with an entering temp of 80

degrees, the temp of the water leaving the condenser is - CORRECT ANSWER: 100

degrees faranheit

A Compound pressure gauge measures - CORRECT ANSWER: Pressure and Vacuum

A compressor that has a broken reed valve will cause these symptoms - CORRECT

ANSWER: high suction pressure and low discharge pressure

A customer complains that their AC system is running constantly, but not cooling enough. The suction line is very colde and the compressor is sweating. Mostlikely cause

is - CORRECT ANSWER: a restriction of the return air or dirty evaporator

A decrease in superheat causes the thermostatic expansion valve to - CORRECT

ANSWER: Close

a dirty evaporator in an AC system will cause these symptoms - CORRECT ANSWER:

low suction pressure and low discharge pressure. 1 / 2

A drain trap should be installed on a split system when the - CORRECT ANSWER: Air handler drain is on the negative side

a faulty condenser fan motor on an AC system will cause these symptoms - CORRECT

ANSWER: high suction pressure and high discharge pressure

A Liquid line filter drier should be placed between the - CORRECT ANSWER:

Condenser and metering device

A liquid reciever is used to - CORRECT ANSWER: Store liquid refrigerant

A liquid-to-suction heat exchanger is often used to - CORRECT ANSWER: Increase

liquid subcooling

A low pressure cut-off switch is used to - CORRECT ANSWER: Establish a minimum

operating pressure in the evaporator

A low refrigerant charge in an AC system will cause these symptoms - CORRECT

ANSWER: low suction pressure and low discharge pressure

A Mechanical shaft seal is necesssary on a - CORRECT ANSWER: Open drive

compressor

a partially clogged capillary tube metering device can cause - CORRECT ANSWER: a starved evaporator

A partially iced over evaporator can be caused by - CORRECT ANSWER: an

undercharge

  • / 2

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 27, 2025
Description:

HVAC EXCELLENCE Latest Update 2025-2026 Actual Exam 100 Questions with 100% Verified Correct Answers Guaranteed A+ Verified by Professor - CORRECT ANSWER: ____ can be used for leak detection with A...

Get this document $30.00