CSLB C10 Test 1 | 120 Questions with 100% CORRECT ANSWER s

Question : What is the minimum working clearance from an

electrical panel under 600 V?

CORRECT ANSWER : 36"

Question : Voltage drop in wire is a function of:

CORRECT ANSWER : Wire gauge, Length of wire, Current

flow in the wire

Question : A 12-volt direct current, 13-watt fluorescent light

is controlled by a photocell. The average daily on-time is 12 hours per day. How many watt-hours are consumed by the light on an average day?

CORRECT ANSWER : 156

Question : Where may you use nonmetallic-sheathed cable?

CORRECT ANSWER : inside floors and walls

Question : What is the maximum permitted distance between

convenience outlets in kitchens?

CORRECT ANSWER : 12'

Question : The minimum permitted size fixture wire is:

CORRECT ANSWER : No. 18

Question : What is an Erickson coupling used for?

CORRECT ANSWER : to connect two sections of rigid

conduit when one section cannot be turned

Question : The smallest size grounding conductor permitted

for service entrance is:

CORRECT ANSWER : No. 8 copper

Question : For an electric appliance with a 17.5 A load, the

overcurrent device must not exceed:

CORRECT ANSWER : 25 amps

Question : A 5 kW appliance is used for 5 hours. At $0.014

per kWh, the cost of running the appliance is:

CORRECT ANSWER : $0.35

Question : If the plumber accidentally cuts installed wires, to

whom should you report the problem?

CORRECT ANSWER : general contractor

Question : What is the maximum distance to an outlet from

any point along the wall behind a kitchen counter?

CORRECT ANSWER : 24"

Question : Which of the following materials is not corrosive?

CORRECT ANSWER : enamel

Question : 65 street lights are fed by a 2275-volt series circuit.

What is the voltage across each light?

CORRECT ANSWER : 35 V

Question : What do you not take into consideration when

doing load demand calculations?

CORRECT ANSWER : small portable heating and cooling

appliances

Question : The symbol represents a:

CORRECT ANSWER : relay coil

Question : A fixture that weighs more than ______ must be

supported independently of an outlet box.

CORRECT ANSWER : 50 lb.

Question : After installing a new A/C how would you test it?

CORRECT ANSWER : turn on the breaker and check

voltage

Question : The symptoms of shock are:

CORRECT ANSWER : pale skin; sweaty; fast pulse

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Questions & answers
Added: Sep 7, 2025
Description:

CSLB C10 TEST 1 (ACTUAL) QUESTIONS AND VERIFIED CORRECT ANSWERS | RATED A+ | LATEST What is the minimum working clearance from an electrical panel under 600 V? 36" Voltage drop in wire is a functio...

Get this document $30.00