CT Registry Review Questions with 100% Verified Correct Answers

  • Which of the following statements is false?
  • The elimination of superimposed structures is a distinct advantage of CT over plain film
  • imaging.

  • CT images possess superior quality.
  • Contrast resolution is approximately 10x better with CT compared to plain film imaging.
  • Spatial resolution is approximately 10x better with CT compared to plain film imaging. - Correct
  • Answer d

  • Which type of beam coverage will result in the greatest production of scatter radiation?
  • Fan beam
  • Pencil beam
  • Area beam
  • Cone beam - Correct Answer d
  • Which type of beam coverage is typical of SDCT systems?

  • Fan beam
  • Pencil beam
  • Area beam
  • Cone beam - Correct Answer a
  • Which type of beam coverage is typical of MDCT systems?

  • Fan beam 1 / 4
  • Pencil beam
  • Area beam
  • Cone beam - Correct Answer d
  • "Translate-Rotate" is in reference to which of the following generations of CT geometries?

  • First
  • ii. Second iii. Third iv. Fourth

  • 1 thru 4
  • 1&2only
  • 3 only
  • 4 only - Correct Answer b
  • Which of the following structures possesses the ability to attenuate radiation the greatest?

  • Air
  • Muscle
  • Bone
  • Soft tissue - Correct Answer c
  • Which of the following structures is represented by the highest Hounsfield Unit?

  • Air
  • Muscle
  • Bone
  • Soft tissue - Correct Answer c
  • Which of the following HU values would be typical of a metallic pacemaker? 2 / 4

  • 2000
  • 1000
  • -500
  • -2500 - Correct Answer a
  • The process in CT by which different tissue attenuation values are averaged to produce one less accurate pixel reading is most likely defined as which of the following?

  • Interpolation
  • Extrapolation
  • Volume averaging
  • Beam hardening - Correct Answer c
  • Which of the following pieces of CT hardware is principally responsible for determining slice thickness when the system is SDCT?

  • Pre-detector collimator
  • Pre-patient collimator
  • The cone beam collimator
  • The fan beam collimator - Correct Answer b
  • From the choices below, please select the best way to minimize the problem associated with Partial Volume Averaging.

  • Select an alternative algorithm
  • Increase the slice thickness
  • Decrease the slice thickness
  • Increase procedure mA - Correct Answer c
  • Segmentation and averaging of the data results in what kind of data?

  • scan data 3 / 4
  • Image data
  • Raw data
  • 2 only
  • 3 only
  • 1&3only d. 1&2only - Correct Answer a
  • As associated with which of the following, does raw data become image data?

  • The detector system
  • The ADC
  • The DAS
  • The voxel - Correct Answer b
  • Which imaging plane divides the body into equal anterior and posterior portions?

  • the MSP
  • the MCP
  • the Axial
  • the Oblique - Correct Answer b
  • Which of the following is NOT housed in the gantry?

  • X-ray source
  • Cooling system
  • Generator
  • Slip ring system
  • Collimation system
  • Detector system
  • 3&6only
  • 1, 3 & 6 only
  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Sep 5, 2025
Description:

CT Registry Review Questions with 100% Verified Correct Answers 1. Which of the following statements is false? a. The elimination of superimposed structures is a distinct advantage of CT over plain...

Get this document $30.00