Electrical Journeyman Test 2024 Latest Update 2024-2025 Actual Exam 200 Questions and 100% Verified Correct Answers Guaranteed A+

"Edison" base "plug" style fuses shall not exceed what voltage and shall not exceed

what current - CORRECT ANSWER: Not over 125V and not over 30A

"Voltage Drop" is equal to what formula (from the EIR circle) - CORRECT ANSWER: E (voltage drop) = I (current) x R (resistance)

(4) "grounding" (EGC) conductors in a device box, for counting cubic inch volume of

space, counts as how many conductors - CORRECT ANSWER: 1 conductor

125 volt to ground service conductors over a pedestrian only wal way, must be a

minimum height of - CORRECT ANSWER: 10 ft

20 ampere circuit has one receptacle (not a duplex) what is the required minimum rating

of the receptacle - CORRECT ANSWER: 20A

A 1" square copper bar in a sheet metal auxiliary gutter, has an ampacity of -

CORRECT ANSWER: 1,000A

A 150A single phase dwelling service, requires a minimum service conductor size of -

CORRECT ANSWER: #1

A bare aluminum grounding electrode conductor must be terminated a minimum of how

far from earth - CORRECT ANSWER: no closer than 18" to the earth

A bathroom is required to have - CORRECT ANSWER: A light switch, electrical outlet and GFCI protection

  • / 3

A box with (2) 14/3 NM, one yoke, and a clamp requires a minimum or _____ cubic inches.

  • 16
  • 18
  • 20

d. 22 - CORRECT ANSWER: c. 20

A box with #10 AWG THHN will require a free space of _____inches.

  • 2
  • 2.25
  • 2.5

d. 3 - CORRECT ANSWER: c. 2.5 (See Table 314.16 (B).)

A building is separate from the main building. Equipment grounding and neutral conductors are ran to the separate building. Where is the separate buildings neutral to

be bonded - CORRECT ANSWER: at the main service (source)

A Ceiling fan fixture may be supported by a standard outlet box, if the fan does not

weigh more than - CORRECT ANSWER: 35 lbs

A ceiling light fixture (luminaire) may be supported be a standard outlet box, if the

luminaire does not weigh more than - CORRECT ANSWER: 50 lbs

A circuit is supplied by a source not more than 1,000 va and not more than 30 volts is a

- CORRECT ANSWER: Class 1 Power Limited Circuit

A commercial garage without ventilation, the space between 18" above the floor is -

CORRECT ANSWER: Class I, Division 2

A conduit protecting the grounding electrode conductor shall be bonded to the ____ at both ends. - CORRECT ANSWER: Grounding Electrode Conductor (See 250.66(E)(1).) 2 / 3

A cord and plug waste disposal (garbage disposal) must have what type of plug, and

what length of cord - CORRECT ANSWER: Grounded plug, 18" to 36" cord

A dwelling at grade level is required to have - CORRECT ANSWER: (2) outside outlets, a laundry circuit, and a minimum 100A electrical service *this may be an "all of the above" or "A, B, and C" type of question*

A dwelling has a detached garage that has a light switch and a non-switched grounded receptacle. How many minimum conductors are run between the dwelling and garage -

CORRECT ANSWER: 3 conductors (hot neutral and EGC)

A dwelling pool must have at least - CORRECT ANSWER: One receptacle

A fixed electrical heating cable must be how far from an electrical outlet - CORRECT

ANSWER: 8"

A fixed light will be allowed to be 30 amp provided the socket is rated ____ duty.

  • Light
  • Medium
  • Heavy

d. Extra Heavy - CORRECT ANSWER: c. Heavy

A free standing office partition is cord and plug connected to the power supply. What is the maximum length of the partition power cord AND what is the maximum distance from the wall or floor receptacle supplying the electrical power to the partition -

CORRECT ANSWER: Maximum cord and plug length is 2 ft. Maximum distance from

the partition to either a floor or wall receptacle supplying electrical power to the partition is 12"

A general use snap switch controlling a 1⁄2 Hp motor load, shall have a switch rating of at least - CORRECT ANSWER: 125% of the motor load

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 30, 2025
Description:

Electrical Journeyman Test 2024 Latest Update 2024-2025 Actual Exam 200 Questions and 100% Verified Correct Answers Guaranteed A+ "Edison" base "plug" style fuses shall not exceed what voltage and ...

Get this document $30.00