EPA 608 Type 1Exam 2023/2024 Questions with Correct Answers A process stub is a _____.

  • straight piece of tubing that is entered using a piercing access valve
  • line located at least 3 inches below the compressor
  • service valve installed at the factory
  • stub to allow additional compressors to be connected in parallel - Correct Answer A) straight piece of
  • tubing that is entered using a piercing access valve A passive system0dependent recovery process _____.

  • uses a pressurized container
  • must still use a pressurized container but no pressure relief device is needed
  • recovers refrigerant in a non-pressurized container
  • needs a system with an operating compressor - Correct Answer C) recovers refrigerant in a non-
  • pressurized container If the refrigerant in a system is suspected to be contaminated, you can _____.

  • turn the refrigerant in for reclamation
  • vent the refrigerant because it cannot be recycled
  • mix the refrigerant with nitrogen, call it a trace gas, leak check, and then vent it
  • mix the refrigerant with virgin refrigerant to lower the contamination - Correct Answer A) turn the
  • refrigerant in for reclamation If you encounter a small appliance that is leaking, _____.

  • you must repair the leak within 30 days
  • you must document all attempts to repair the leak 1 / 3
  • you do not have to repair the leak
  • you must recover all remaining refrigerant and dispose of the appliance - Correct Answer A) you must
  • repair the leak within 30 days Solderless piercing valves should never remain permanently installed because they _____.

  • violate EPA regulations
  • violate SNAP regulations
  • tend to leak over time
  • trap lubricant and cause compressor failure - Correct Answer C) tend to leak over time
  • Low-loss fittings _____.

  • can be either manually closed or automatically closed when disconnected to prevent loss of
  • refrigerant from hoses

  • only leak small amounts of refrigerant during use
  • are no longer required to be used because refrigerants are greener
  • reduce oil losses during refrigerant recovery - Correct Answer A) can be either manually closed or
  • automatically closed when disconnected to prevent loss of refrigerant from hoses When a pungent odor is detected in the oil, _____.

  • the refrigerant should not be recovered; instead vent it
  • a compressor burnout has probably occurred
  • it is POE oil
  • All of the above - Correct Answer B) a compressor burnout has probably occurred
  • it is POE oil
  • All of the above
  • At high temperatures, CFC and HCFC refrigerants can decompose into _____. 2 / 3

  • hydrazine gas
  • phosgene gas
  • hydrogen gas
  • chlorine gas - Correct Answer B) phosgene gas
  • When a tank of mixed refrigerant is sent to a reclaimer, they can _____.

  • refuse to accept the refrigerant
  • charge extra for processing it
  • vent the refrigerant
  • either A or B - Correct Answer D) either A or B
  • CFC and HCFC refrigerants can decompose to from _____.

  • boric acid
  • sulfuric acid
  • hydrochloric and hydrofluoric acids
  • phosphoric acid - Correct Answer C) hydrochloric and hydrofluoric acids
  • HC refrigerant systems require permanent safety markings _____.

  • on or near any evaporators and near any exposed refrigerant tubing
  • near the machine compartment
  • on the exterior of the refrigerator
  • at all of the above locations - Correct Answer D) at all of the above locations
  • Low- and high-side access valves can be installed instead of a single access valve _____.

  • to speed-up recovery
  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Questions & answers
Added: Sep 5, 2025
Description:

EPA 608 Type 1Exam Questions with Correct Answers A process stub is a _____. A) straight piece of tubing that is entered using a piercing access valve B) line located at least 3 inches below the co...

Get this document $30.00