EPA 608 UNIVERSAL EXAM 2024-2025 WITH

EXAM ELABORATIONS Aug 28, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

pg. 1

EPA 608 UNIVERSAL EXAM 2024-2025 WITH

400 REAL EXAM QUESTIONS AND 100%

CORRECT ANSWERS (GUARANTEED A)/

EPA 608 UNIVERSAL EXAM (NEW!!)

Equipment covered by EPA regulations include: - all air-conditioning and

refrigeration equipment using CFC, HCFC or HFC refrigerants.

All devices used for a refrigerant recovery must: - Meet EPA standards

Reusable refrigerant containers that are normally under any pressure above 15 pig

must be hydrostatically tested and date stamped every: - 5 Years

The EPA can require a technician to demonstrate their ability to perform proper procedures for recovering and/or recycling refrigerant. Failure to demonstrate

competency can result in: -revocation of the technicians certification.

Refrigeration technicians who violate the Clean Air Act can: -Lose their EPA

certification, be fined, be required to appear in Federal court.

An award of up to what amount may be paid to a person supplying information that leads to a penalty against a technician who is intentionally venting? - 10,000

Which atom of the CFC molecule causes ozone depletion? - chlorine

The ozone layer protects the earth from: - ultraviolet radiation from the sun.

  • / 4

pg. 2 After 1995, any supplies of CFC refrigerants to service existing units in the USA

can only come from: -recovery and recycling.

Refrigerant that is recovered can be returned to: -the same system or other systems owned by the same person without restriction.

Refrigerant can not be called "reclaimed" unless it: - .has been chemically analyzed and the refrigerant meets the ARI-700 standard.

What characteristic(s) of CFCs make them more likely to reach the stratosphere than most other compounds containing chlorine? -Refrigerants that contain chlorine but not hydrogen are so stable that they do not break down in the lower atmosphere after being released. The chlorine or bromine reacts with the ozone, causing it to change back to oxygen, thus destroying the ozone layer.

A system is considered dehydrated when: -the vacuum indicator shows you have

reached and held the required finished vacuum.

Disposable refrigerant containers are used for ______virgin refrigerant

Which refrigerant is an HCFC? -R-123, R-124, R-22

What statement is true about an azeotropic refrigerant mixture? -It is a mixture that acts like a single-component refrigerant over its entire range.

Chlorofluorocarbos (CFCs) and hydrochlorofluorocarbons (HCFCs) have which of the following in common? -It is a mixture that acts like a single-component refrigerant over its entire range.

  • / 4

pg. 3 To scrap a disposable cylinder, the internal cylinder pressure should be reduced to

at least: -0 psig.

Manifold gauge sets are often color coded, when this is done, the high pressure

gauge is color coded: - Red.

In general, blended refrigerants should be charged: -as a liquid.

Blended refrigerants leak from a system: -in uneven amounts due to different vapor pressures.

Which of the following gases help form the earth's protective shield? - Stratospheric Ozone

In a refrigerant system, the device that changes a low pressure vapor to a high

pressure vapor is the: - compressor.

Data shows that chlorine in the stratosphere comes mainly from CFCs rather than

from natural sources such as volcanoes because: - The rise in the amount of

chlorine in the stratosphere matches the rise in the amount of fluorine, which has different natural sources than chlorine; The rise in the amount of chlorine in the stratosphere matches the rise in CFC emissions; Air samples taken from the stratosphere over erupting volcanoes show that volcanoes contribute a small quantity of chlorine to the stratosphere when compared to CFCs;

When using with any solvent, cleaner, chemical or refrigerant, you should review:

  • material safety data sheets.

The Montreal Protocol is: - a treaty among nations that controls production of

CFCs and HCFCs. 3 / 4

pg. 4

Which refrigerant is an HCFC? - R-123, R-22, R-124

What is one of the most serious results of damage to the ozone layer? - increases in human skin cancer

Of the refrigerants listed below, which has the lowest ozone depletion potential

(ODP)? - R-22

To determine the maximum allowable pressure to use when checking a system,

check: - the design pressure on the equipment nameplate

Ozone depletion potential, or "ODP," is: - A measure of the ability of CFCs and HCFCs to destroy ozone.

An example of an HFC refrigerant is: - R-134a

Whenever dry nitrogen from a portable cylinder is connected to a system, what item is of most importance in consideration of safety? - There is relief in the downstream line from the pressure regulator.

During servicing of a refrigeration system containing R-12, the refrigerant must be:

  • recovered.

Which safety precaution(s) should always be followed: - Never apply an open

flame to a refrigerant cylinder; never cut or weld any refrigerant line when refrigerant is in the line; never use oxygen to purge lines or to pressurize a system.

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 28, 2025
Description:

pg. 1 EPA 608 UNIVERSAL EXAM 2024-2025 WITH 400 REAL EXAM QUESTIONS AND 100% CORRECT ANSWERS (GUARANTEED A)/ EPA 608 UNIVERSAL EXAM (NEW!!) Equipment covered by EPA regulations include: - all air-c...

Get this document $30.00