Essentials of Fire Fighting 7th Edition
- Chapter 3: Building Construction
Type I construction building are considered to be:
- More collapse resistant than other building types
- More likely to suffer structural damage due to the effects of fire
- The most common type of residential construction encountered by firefighters
- Hazardous due to the adhesives and industrial glues used during the
construction process - ANSWER A.More collapse resistant than other building types Chapter 3 - page 78
Multi-story buildings with flat roofs usually have:
- Cast-in-place concrete roofs
- Roof decking made of corrugated steel
- The same structural system for the roof and the floors
- Different types of structural support systems for every floor -
ANSWER C. The same structural system for the roof and the floors Chapter 3 - page 95 1 / 3
Which window component is the lowest horizontal member of the frame and supports the window hardware?
- Sill
- Sash
- Jamb
- Glazing - ANSWER A. Sill
- Firefighters should attempt to manually close the fire door when they encounter
- A significant amount of smoke may flow through the door before the door is
- The door will close much faster than doors that require a smoke detector to
- The fire door is more easily tested than doors that require a smoke detector to
- A significant amount of smoke may flow through the door before the door is
- They pose a significant electrical shock hazard
- They are unable to be penetrated with normal firefighting tools
- They are designed with small open spaces that provide oxygen to the fire 2 / 3
Chapter 3 - page 108 A fusible link on a swinging fire door depends on the heat from a fire to close, so:
it
released
activate the closing mechanism
activate the closing mechanism - ANSWER
released Chapter 3 - page 108 What is one major problem that rain roofs pose for firefighters?
- They create a void that conceals fires and allows them to burn undetected -
ANSWER They create a void that conceals fires and allows them to burn undetected Chapter 3 - page 100
The lightweight members of a truss assembly are:
- Usually made almost completely of aluminum
- Susceptible to early failure when exposed to fire
- Usually made almost completely of composite plastic
- Able to withstand fire longer than thicker truss components -
ANSWER B. Susceptible to early failure when exposed to fire Chapter 3 - page 94
Overhead rolling steel fire doors:
- Are often used to protect openings in the required path of egress
- Ordinarily close under the force of gravity when the fusible link melts
- Are unpopular because they use wall space on both sides of the opening
- Function by closing when prompted by an automated closing mechanism -
- / 3
ANSWER B. Ordinarily close under the force of gravity when the fusible link melts Chapter 3 - page 106