EVITP Modules 5 - 7 Questions and Verified Answers (Latest 2024 / 2025 Update) Grade A | 100% Correct
Question:
The most commonly reported repair to electric vehicle supply equipment (EVSE) manufacturers is damage to the ___ ?
- contractor
- cord set
c) EVSE
- panelboard
Answer:
cord set
Question:
Issues with data servers, EVSE locator networks, and billing networks are typically the result of an ___ problem
- communication
- contractor
- ground fault
- overcurrent protection
Answer:
communication 1 / 3
Question:
Public EVSE installations need to be protected from ___ vehicles and maintenance equipment
- impacts with
- rain on
- theft of
- vandalism of
Answer:
impacts with
Question:
The first step in the troubleshooting and repair guidelines flowchart is to ___ ?
- document make, model, & serial numbers
- locate panel & check circuit breaker
- test unit using an EVSE simulation
- visually inspect EVSE
Answer:
visually inspect EVSE
Question:
The final step in the troubleshooting and repair guidelines flowchart is to ___?
- document make, model, & serial numbers
- recommission EVSE
- release EVSE as fully operational 2 / 3
- test unit using an EVSE simulator
Answer:
release EVSE as fully operational
Question:
For information regarding specific tools required for servicing EVSE installed in public locations that use tamper-resistant hardware, one should refer to ___ ?
- manufacturers instructions
b) NFPA 70 NEC
c) NFPA 70E standard for electrical safety in the workplace
d) OSHA CFR1926
Answer:
manufacturers instructions
Question:
The ___ section of the troubleshooting and repair guidelines flowchart outlines issues specific to testing and procedures and may also be used as a sequence of events
- 1
st
- 2
nd
- 3
rd
- 4th
Answer:
2nd
- / 3