FANUC SECE Test Questions with Correct Answers 100% Verified T/F: Dual Check Safety position/Speed features do not need additional external sensors to monitor speed and position - Correct Answer True What is the correct way to recover from a DCS Joint Position Check alarm? - Correct Answer Press SHIFT + RESET and then jog away from the limit.Which of the following allows you to enable DCS Cartesian Speed Check? - Correct Answer *Program instruction *Setting on the DCS Cartesian Speed Check menu *System Variable setting **All of the above** The DCS OPSFTY signals are hardwired to which unit on the R-30iB Controller? - Correct Answer Emergency Stop Board There are two levels of DCS Code numbers Master and Local. The Local are...? - Correct Answer Base, Position/Speed Check, and I/O Connect If updated in Non-DCS menus, what does not need to be applied to the DCS Parameter? Hint: Consider ALL possible setup situations - Correct Answer Axis limits The maximum number of Cartesian Position Check Zones? - Correct Answer 32 If creating a model for your tooling what is the maximum number of shape elements that can be used? - Correct Answer 10 T/F: A Maximum of 5 elements can be combined to result in a single Output per line. - Correct Answer False Guarding a Zone against more than three USER MODELS is done with: - Correct Answer The Tool Change Function 1 / 2
To Cycle Power from the teach pendant? - Correct Answer Make sure the teach pendant is ON. Then press the FCTN, Select CYCLE POWER.When replacing the regenerative resistor unit on an A-cabinet... - Correct Answer Remove the side panel and the louver and then two screws will allow for removal of the unit.If you hold PREV and NEXT on the TP while applying power to the controller, eventually the following screen will appear? - Correct Answer Configuration Menu An error code SRVO-075, Pulse Not Established indicates? - Correct Answer Each axis that lost mastering must be rotated one motor revolution If the input fuse, F1, on the power supply is blown, you will have? - Correct Answer No display on the teach pendant A blown input fuse, F1, on the power supply could be caused by? - Correct Answer A shorted fan wire harness The Emergency stop button on the SOP will? - Correct Answer Remove the nominal 220VAC three phase from the servo amplifier Power supply regeneration refers to? - Correct Answer A method whereby excess motor power is fed back into the supply line.A new battery can maintain the contents of SRAM memory for about? - Correct Answer Four Years Robot positional feedback is provided by? - Correct Answer Serial Pulse Coder The battery pack in the base of the robot provides power to? - Correct Answer The motor SPCs The relays contacts which bring power to the coils of KM1 and KM2 are located on the? - Correct Answer Emergency stop circuit board
- / 2