FDNY S-92 E xam Study Guide 105 Questions with Correct Answers 2024 The following are types of what? LPG, CNG, piped natural gas or solid fuel (coke). - Correct Answer Portable fueled salamanders/space heaters National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL) for carbon monoxide - Correct Answer 35 parts per million (ppm) over an 8 hour period What is the third leading cause of fires in buildings under construction ? - Correct Answer temporary heating What is direct heat flow through matter? - Correct Answer CONDUCTION What is the transport of heat within a gas or liquid caused by the actual flow of the material itself - Correct Answer CONVECTION the transmission of electromagnetic rays through space. - Correct Answer Radiation Heaters that release all of the heat generated by the flame (and the emissions that result) directly into the heated area - Correct Answer Direct-fired heaters What are the most common type of heater found at construction sites? - Correct Answer Direct-fired heaters The flame of this heater is enclosed in a heat exchanger that separates combustion products from the air to be heated. - Correct Answer Indirect-Fired Heaters When may portable oil-fueled space heaters be stored, handled and used at construction sites - Correct Answer only during the heating season (October 15th - May 30th). 1 / 2

A fail-safe system or other approved device, equipment or system designed to shut off flow caused by a rupture in a pressurized piping system. - Correct Answer EXCESS FLOW CONTROL A liquefied compressed gas which, under a charged pressure, is partially liquid at a temperature of 68°F (20°C) and which is a flammable gas. - Correct Answer FLAMMABLE LIQUEFIED GAS supervision by the holder of any department certificate who is responsible but need not be personally present on the premises at all times - Correct Answer GENERAL SUPERVISION A material having a melting point that is equal to or less than 68°F (20°C) and a boiling point that is greater than 68°F (20°C) at 14.7 psia (101 kpa). - Correct Answer LIQUID The minimum concentration of vapor in air at which propagation of flame will occur in the presence of an ignition source. The LFL is sometimes referred to as LEL or lower explosive limit - Correct Answer LOWER

FLAMMABLE LIMIT (LFL)

The transfer of flammable or combustible liquids between cargo tanks or tank cars and containers, tanks piping and other equipment that is to be used in process operations. - Correct Answer PROCESS TRANSFER what shall be on site and available for inspection at all times? - Correct Answer All FDNY original permits A method of supervision by the holder who is required to be personally present on the premises - Correct Answer PERSONAL SUPERVISION

  • / 2

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Sep 5, 2025
Description:

FDNY S-92 E xam Study Guide 105 Questions with Correct Answers 2024 The following are types of what? LPG, CNG, piped natural gas or solid fuel (coke). - Correct Answer Portable fueled salamanders/s...

Get this document $30.00