FF2 Chapter 21 Maintenance and Testing Responsibilities IFSTA
Power tools should be inspected: - ANSWER
at the beginning of every shift.Which location would be ideal for testing fire hose? - ANSWER Empty parking lot next to the fire station Which action should be avoided when service testing fire hose because it can cause damage to the hose? - ANSWER Testing hose in an area with rocks and debris
When service testing a fire hose, it is necessary to: - ANSWER
have access to a water source that is sufficient for charging the hose.When inspecting and maintaining a portable generator, the generator can be damaged if: - ANSWER it is run for a long period of time without a load.
Fire hose testing records should include the: - ANSWER
reason that any hoses fail the test. 1 / 2
Which is an indicator that a fire hose should be removed from service? - ANSWER Couplings are loosening from the hose When replacing bulbs on portable scene lighting equipment, it is important to: - ANSWER allow the bulb to cool before replacing it.Which type of equipment is NOT typically maintained by a Fire Fighter II? - ANSWER Apparatus electrical systems Which piece of equipment is used to prevent pressurized hose from dangerously whipping back and forth if it ruptures? - ANSWER Hose test gate valve Which pieces of equipment are necessary to service test a fire hose? - ANSWER Hose-testing machine, portable pump, or fire department pumper
When maintaining portable lighting equipment, it is safest to: - ANSWER
connect each light to the generator one at a time.
Replace any spark plug that: - ANSWER
shows signs of arcing.
- / 2