Florida LP Gas & Rules Exam Questions with Complete Solutions 100% Verified
Licensed Locations Qualifier:
- Full Time Employee
- Non-Supervisory Position
- Multiple Locations
- All of the Above - Correct Answer A) Full Time Employee
Vacancies in Qualifier must be reported:
- By the qualifier
- By the licensed company
- 20 Working Days
- 60 Working Days
- All of the above - Correct Answer E) All of the above
- True
- False - Correct Answer A) True
- True
- False - Correct Answer B) False
- Not to exceed $1,300
- Exceed $3,000
- Not to exceed $2,000
- Not to exceed $3,000 - Correct Answer D) Not to exceed $3,000 1 / 3
Is the Bureau of Compliance is currently responsible for licensing, exams and training.
Qualifier means any business who has passed a competency examination administrated by the department and is employed by a licensed Cat I, II, V business.
Qualifier means any Person who has passed a competency examination administrated by the department and is employed by a licensed Cat I, II, V business.The Department may impose civil or administrative penalties in the Class II category, ________ for each offense, suspend or revoke the license.
Qualifier automatically expires if you terminate active employment in the area of examination for a period
- Exceeding 24 days
- Exceeding 30 months
- Exceeding 24 months
- Exceeding 24 days - Correct Answer C) Exceeding 24 months
A cylinder exchange unit must have what signage affixed to the front of the unit and all approachable
sides:
- Propane
- Flammable Gas
- No Smoking
- All of the Above - Correct Answer D) All of the Above
- True
- False - Correct Answer A) True
- 11
- 10
- 12
- 9 - Correct Answer B) 10
- 20
- 21
- 19
- None of the Above - Correct Answer D) None of the Above 2 / 3
Documentation shall be maintained at the employee's place of business and shall be available for inspection by the department upon request.
Pressure relief devices installed in underground dispensing tanks shall be piped vertically upward of _____ feet above the ground.
No person under the age of ___ years shall be permitted to dispense propane.
Age of 18 years Which Category License can requalify cylinders?
- Cat I
- Cat 2
- Cat 3
- Cat 4 - Correct Answer A) Cat 1
- 1
- 12
- 24
- 48 - Correct Answer C) 24
- 10
- 11
- 12
- 24 - Correct Answer C) 12 months
- Annex B
- Annex C
- Annex L
- None of the Above - Correct Answer B) Annex C of the NFPA 54
- A Truck Meter (>20 gpml)
- A Dispenser Meter (<20 gpml)
- / 3
A person, firm, or corporation who disconnects any container or system shall notify the owner of the container or system within ____ hours.
Vehicle fuel dispensers or dispensing stations which have been inactive ( out of service) for a period of ____ months shall be removed from the premises.
According to what NFPA 54 Annex can you find the methods for leak test as incorporated by reference in rule 5J-20.002, F.A.C?
When must you the appropriate Weights & Measures Permit?