G-60, G60, F-60 FIRE GUARD, F-60
STUDY MATERIAL 250 QUESTIONS AND
ANSWERS
G-60 - answer Use of oxygen and flammable gasses, or LPG or CNG for any hot work COF exception - answer Torch operations for jewelry FDNY permit - answer Storing using or handling oxygen and flammable gas in excess of 400scf (LPG, CNG or scetylene) oxidizing gass in excess of 504scf Portable LPG must not be stored when the capacity of the container is greater than? - answer 16.4 oz Portable CNG containers must not be stored then the capacity is greater than? - answer 8.7 SCF Single standard portable LPG containers must not exceed? - answer 100LBs in weight Single CNG containers must not exceed? - answer 381 SCF LPG 400 SCF is approximately - answer 47 lbs 1 / 4
Types of FDNY permits - answer Site specific permits City wide permits Transportation permits Site specific permit can be? - answer Can be permenant or temperary Permanent permits are valid for how long? - answer 12 months only.Permits and renewals require inspection and will expire adter twelve months.Temporary permits may be valid from? - answer One day to 12 months depending on the construction or operations needed.City wise permit duration? - answer 30 days Hazards out end of day Quantity of hazardous material being stored(maximum)? - answer 5 gals gasoline 250 gals of flammable 300 gals combustible liquid Transportation permit - answer FDNY approved inspected displayed on vehicle Hot work authorization. - answer Required for any project with hot work operation but not issued by the FDNY 2 / 4
Responsible person - answer Must be available for inspection by any representative of fire department during and 48 hours after the work is complete.Fire guard - answer Cof holder who is trained in and responsible for maintaijjng a fire watch.Fire watch - answer Survailance of an area Detect signs of early fire Raise alarms Notify department Pre hot work check must be conducted by the responsible person before hot work is authorized at least? - answer Once per day Pre hot work check daily and must very the following - answer Equipment working in order Hot work is clear of combistibles and flammable solids Combustible and non combustible are protected Fire watch personel are assigned Fire extinguisher available Fire watch - answer A fire watch must be maintained during any hot work operation.The person conducting a fire watch shall - answer Not have other duties 3 / 4
Fire watch At least one portable fire extinguisher with a - answer Minimum 2-A:20-B:C rating shall be accessible within 30ft from hot work Fire watch
Exception roofing operating fire extinguisher - answer 3-A 40-B:C
Fire watch for torch operations conducted at following locations by a F-60 fire guard: - answer Construction sites Buildings and structures Rooftops Fire watch must continue for - answer 30 minutes after the conclusing of the work.Time and record keeping requirements CNG or LPG torch operations inspections - answer First shall be conducted 30minute after completion Second inspection 1 hour after completion The inspection report must be available - answer 48 hours after work is complete for fire department representative to look over.
- / 4