GXMO State Board exam Latest Update 2025- 2026 Actual Exam 100 Questions with 100% Verified Correct Answers Guaranteed A+ Verified by Professor A device for removing long wavelength radiation from the primary x-ray beam is a:

  • collimator
  • rheostat
  • rectifier

D. filter - CORRECT ANSWER: D. filter

A device to protect the film from being fogged by scatter radiation is called a(n):

  • collimator
  • detent
  • grid

D. IR - CORRECT ANSWER: C. grid

A device used to measure the current flowing in a series circuit is a(n):

  • voltmeter
  • ammeter
  • transformer

D. rectifier - CORRECT ANSWER: B. ammeter

A film that has been exposed but has not yet been processed has a pattern of exposure

that is called the: 1 / 3

  • latent image
  • visible image
  • remnant radiation

D. radiation field - CORRECT ANSWER: A. latent image

A larger actual focal spot yields:

  • greater image sharpness
  • greater tube heat capacity
  • lower patient dose
  • more characteristic radiation - CORRECT ANSWER: B. greater tube heat capacity

A line in the center of the x-ray beam and perpendicular to the long axis of the x-ray

tube is called the:

  • radiation field
  • primary X-ray beam
  • x-ray tube

D. central Ray - CORRECT ANSWER: D. central ray

A mechanism that tends to stop a moving part in a specific location is called a:

  • collimator
  • control console
  • transformer

D. detent - CORRECT ANSWER: D. detent 2 / 3

A photon is a minute quantity of:

  • electromagnetic energy
  • electric energy
  • nuclear energy

D. matter - CORRECT ANSWER: A. electromagnetic energy

A smaller effective focal spot yields:

  • greater tube heat capacity
  • lower patient dose
  • more characteristic radiation

D. greater image sharpness - CORRECT ANSWER: D. greater image sharpness

A steeper target angle provides:

  • more heat capacity
  • lower patient dose
  • less anode heel effect
  • smaller effective focal spot - CORRECT ANSWER: D. smaller effective focal spot

A tilting table will allow the head end to be lowered at least 15 degrees into the:

  • Trendelenburg position
  • Sims position
  • Fowler position
  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 27, 2025
Description:

GXMO State Board exam Latest Update 2025- 2026 Actual Exam 100 Questions with 100% Verified Correct Answers Guaranteed A+ Verified by Professor A device for removing long wavelength radiation from ...

Get this document $30.00