Hematology in Practice 3rd Edition Ciesla Test Bank Chapter 1. Introduction to Hematology and Basic Laboratory Practice Multiple Choice
1. Tube length when referring to the microscope is the:
- Resolution power of the objective
- Distance from the eyepiece to the objective
- Numerical aperture
- Magnitude of the image on the stage
ANS: B
OBJ: 1.3
- What is the most useful corrective action for the microscope when fine details cannot be
- Open up the diaphragm for maximum light.
- Wipe off lenses with lens cleaner.
- Get a new slide.
- Move to a lower power.
visualized in immature cells?
ANS: A
OBJ: 1.4
- Which of the following behaviors is a violation of standard precautions?
- Hand washing after glove removal
- Use of impermeable laboratory gowns
- Use of goggles and face shields
- Placing laboratory notebooks on laboratory work area
ANS: D
OBJ: 1.5
4. Standards and calibrators differ from control materials because:
- An exact amount of analyte is present in a standard or calibrator
- A variable amount of analyte is present depending on patient samples
- Standards only need to be within a target range 1 / 4
- Standards are run to the best estimate of the known value
ANS: A
OBJ: 1.7
- Which of the following is involved in the study of hematology and used to determine sickness
- Quantity of cells
- Cellular structure
- Cellular function
- All of the above
and health?
ANS: D
OBJ: 1.1
- Proper mixing of samples and timely delivery of samples to the laboratory are both examples
of:
- Delta checks
- Postanalytic variables
- Preanalytic variables
- Reflex testing
ANS: C
OBJ: 1.8
- A delta check is a historical reference on samples run in the laboratories. Once a sample fails a
delta check, the most obvious corrective action is to:
- Verify the identification of the patient sample
- Reestablish the parameters of the delta check
- Perform reflex testing
- Perform a manual method
ANS: A
- Which of the following is the definition of a reference interval?
- A solution of a known amount of analyte
- Materials analyzed concurrently with unknown samples
- Values established for a particular analyte, given a method, instrument, or patient population 2 / 4
- Validation techniques on flagged samples
ANS: C
OBJ: 1.8
- Which of the following is not considered a postanalytic variable?
- Delta checks
- Proper anticoagulant used
- Specimen checked for clots
- Calling critical results
ANS: B
OBJ: 1.8
- Error analysis, standard protocols, and turnaround time are all part of the:
- Quality assurance system
- Quality control program
- Reference standards
- Delta check protocol
ANS: A
OBJ: 1.7
11. The average of a group of data points is defined as the:
- Mean
- Mode
- Median
- Modicum
ANS: A
OBJ: 1.7
- Safety training is part of new employee training in health care and includes:
- Biological hazards
- Chemical hazards
- Environmental hazards
- All of the above 3 / 4
ANS: D
OBJ: 1.6
- When viewing a slide with the 50 objective lens, the total magnification being used is:
A. 50
B. 100
C. 500
D. 5000
ANS: C
OBJ: 1.3
14. Delta checks are used in the hematology laboratory to:
- Compare past patient results with the current result
- Verify control accuracy
- Establish a target range
- Establish reference ranges for a particular analyte
ANS: A
OBJ: 1.8
- When hand washing after a patient contact, the soap application process should last at least:
- 5 seconds
- 15 seconds
- 20 seconds
- 30 seconds
ANS: B
OBJ: 1.6
- Which of the following represents an example of a safety violation in the laboratory?
- Application of cosmetics
- Mouth pipetting
- Consuming bottled water
- All the above
ANS: D
OBJ: 1.6
- / 4