what is a clinical manifestation of renal cell carcinoma - ANSWER - hematuria

which of the following may be caused of postrenal acute renal failure (ARF) - ANSWER - obstruction in the ureter or the urethra

what is the target blood pressure (BP) reccomended by the joint national committee on prevention, detection, evaluation and treatment if high blood pressure in patients with CKD? - ANSWER - less that 130/80

common skin changes related to CKD stage 5 include - ANSWER - brittle nails and Ecchymosis

the dialysis technician assists with nursing management of constipation

in CKD patients by: - ANSWER - encouraging a diet high in fiber

some causes of anemia in CKD patients include: - ANSWER -

1.decreased production of erythropoietin loss of blood through the GI tract

  • / 3
  • | P a g e

pg. 2 signs/symptoms of anemia in CKD patients include - ANSWER - dyspnea and fatigue

what is the recommended treatment for osteodystrophy in CKD patients

  • ANSWER - a diet high in protein

most patients who have been on dialysis for over(blank) will have dialysis amyloidosis (DA) - ANSWER - 3 years

CKD patients are at risk for developing peripheral neuropathy, which

may manifest as: - ANSWER - 1. burning feet

  • restless legs

what are advantages of hollow fiber dialyzers compared to parallel plate dialyzers - ANSWER - 1. the ultra filtration is precisely controlled

  • they can be reused

patients sensitive to ethylene oxide sterilization techniques may benefit from (blank) because it does not use chemicals or radioactive materials - ANSWER - electron beam sterilization

what are some negative aspects of synthetic membranes - ANSWER - 1.they are expensive

  • they require automated ultrafiltration control
  • they can absorb proteins on the membrane surface 2 / 3
  • | P a g e

pg. 3 long term exposure to cellulosic membranes used during dialysis has been associated with - ANSWER - 1.infection 2.malignancy

what are the effects of over mixing the bicarbonate concentrate - ANSWER - the patient can experience an increase in sodium levels

which lab test is utilized to detect and quantify bacterial endotoxins - ANSWER - limulus amebocyte lysate (LAL)

During a dialysis session, it is important for the dialysis technician to monitor dialystate temperature since fluid temperature (blank) will result in hemolysis of red blood cells (RBCs) - ANSWER - >41 c

what action should be taken if a blood leak detector alarm is activated and no blood can be confirmed on visual inspection of the site? - ANSWER - check the dialysate with a hemastix

how can air enter the dialysis blood lines - ANSWER - 1. At connections that are not absolutely tight

  • By osmosis thru contract with blood tubing

high efficiency dialysis requires - ANSWER - highly permeable cellulosic membrane with surface area of 1.5 m or more

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 28, 2025
Description:

pg. 1 HEMODIALYSIS ANDERSON CCHT EXAM NEWEST 2025 ACTUAL EXAM| COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VER IFIED ANSWERS) GRADED A+ (BRAND NEW!!) what is a clinical manifestation of renal ...

Get this document $30.00