HVAC BOMA 501 Actual Exam Version 1,2 3

EXAM ELABORATIONS Aug 29, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

  • | P a g e

HVAC BOMA 501 Actual Exam Version 1,2 & 3 (3 Latest Versions) Newest 2025/2026 With Complete Questions And Correct Answers |Already Graded A+||Brand New Version!

VERSION 1

If the resistance against a propeller fan is doubled, the cfm output decreases, but the amperage draw of the motor ___.

  • decreases
  • increases
  • stays the same
  • overheats the motor - ANSWER-b. increases

Which of the following represents a different temperature than the other three?

  • 15°C
  • 59°F
  • 475°K
  • 519°R - ANSWER-c. 475°K 1 / 4
  • | P a g e

The best method of leak checking is when the refrigeration system is ____.

  • in a vacuum
  • open to the atmosphere
  • operating with all fans activated
  • standing with dry nitrogen pressure of 150 psig in the system. -
  • ANSWER-d. standing with dry nitrogen pressure of 150 psig in the system.

Technician "A" says that if the air filter on an air-conditioning system is totally blocked with dirt, the amperage draw of the evaporator fan motor will go down. Technician "B" says that if you close down one supply register on a duct system, the volume of air feeding the other locations will increase slightly. Which of the following statements is correct?

  • Technician "A" is correct. Technician "B" is correct.
  • Technician "A" is correct. Technician "B" is incorrect.
  • Technician "A" is incorrect. Technician "B" is correct.
  • Technician "A" is incorrect. Technician "B" is incorrect. - ANSWER-
  • Technician "A" is correct. Technician "B" is correct.

The refrigerant in a refrigeration system changes state in the ____. 2 / 4

  • | P a g e
  • condenser and compressor
  • compressor and expansion device
  • expansion device and evaporator
  • condenser and evaporator - ANSWER-d. condenser and evaporator

The amount of heat needed to change the temperature of a substance will vary with the type of substance.This heat quality is called the ___ of the substance.

  • sensible heat
  • specific heat
  • latent heat
  • relative heat - ANSWER-b. specific heat

Oil pressure safety controls measure the difference in pressure between the ___.

  • oil pump inlet and discharge pressures
  • oil pump discharge pressure and compressor head pressure
  • oil pump inlet pressure and compressor suction pressure
  • oil pump discharge pressure and compressor crankcase pressure -
  • ANSWER-d. oil pump discharge pressure and compressor crankcase pressure 3 / 4

  • | P a g e

On a 95°F day, the R-22 refrigerant pressure on the high side should be about ____ psig.

  • 182
  • 108
  • 297
  • 243 - ANSWER-d. 243

The pressure in a refrigeration system is changed in the ___.

  • condenser and compressor
  • compressor and expansion device
  • expansion device and evaporator
  • condenser and evaporator - ANSWER-b. compressor and expansion
  • device

If the resistance against a centrifugal blower is doubled, the cfm output decreases, and the amperage draw of the motor ___.

  • decreases slightly
  • increases slightly
  • stays the same
  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 29, 2025
Description:

HVAC BOMA 501 Actual Exam Version 1,2 & 3 (3 Latest Versions) Newest With Complete Questions And Correct Answers |Already Graded A+||Brand New Version! VERSION 1 If the resistance against a propell...

Get this document $30.00