What is the maximum allowable voltage between conductors on a branch circuit supplying lighting fixtures (luminaires) in a residence? - ANSWER- 120 volts

What is the minimum number of 20-ampere branch circuits for small appliances required in a residence? - ANSWER- 2

Branch circuits that serve a ___ are required to be rated at 20 amperes where installed in a house. - ANSWER- a.bathroom b.kitchen c.laundry room d.all of the above (correct)

Branch circuits are rated according to ___. - ANSWER- the ampere rating of the overcurrent device

  • / 4
  • | P a g e

Refer to the Article 100 definition for continuous load in the NEC®. According to 210.19(A) the branch-circuit conductors for a continuous load shall be sized at not less than ___ of the current drawn by the load. - ANSWER- 125%

The smallest permissible wire size for branch circuit conductors supplying other than cooking appliances is ___ AWG according to the NEC®. - ANSWER- 14

When several receptacles are connected to a 20-ampere branch circuit, these receptacles are required to be rated ___. - ANSWER- 15 or 20 amperes

A ___-amp circuit breaker is the largest that can be installed on a 12 AWG copper circuit conductor. The circuit is connected to several receptacles. - ANSWER- 20

When a single receptacle is connected to a branch circuit (the circuit has no other loads), the receptacle must have an ampere rating ___ the ampere rating of the OCPD protecting the branch circuit. - ANSWER- greater than or equal to

Branch circuits are rated according to their ___. - ANSWER- overcurrent protective device rating

  • / 4
  • | P a g e

The maximum permitted current rating of a portable appliance on a 30-ampere branch circuit is ___ amps. - ANSWER- 24

What is the minimum size THHN/THWN wire permitted to serve a load that will draw 47 amps? The load will operate for about 5 hours at a time. The branch-circuit OCPD is a circuit breaker that is rated for 75°C. - ANSWER- 6 AWG`

In a dwelling, a living room branch circuit with a 20-ampere rating can be loaded to a maximum of ___ amperes. -

ANSWER- 20

Fastened-in-place utilization equipment that is connected to a branch circuit with other loads shall not exceed ___ percent of the branch circuit rating. - ANSWER- 50

Along a kitchen countertop in a restaurant, the maximum spacing between receptacles is ___. - ANSWER- not specified

Receptacles in a finished basement must be installed such that no point measured horizontally along the floor line of any wall space is more than ___ feet from a receptacle outlet. -

ANSWER- 6

  • / 4
  • | P a g e

Refer to Figure 108.014. This kitchen is in a house and width of the countertop where receptacle 9 is located is 13″. Is receptacle

  • required by the NEC®? - ANSWER- yes

Where fixed glass panels (i.e., windows or non-sliding parts of doors) do not permit installation of wall-mounted receptacles, ___ are typically used to satisfy the receptacle spacing requirements of NEC® 210.52(A)(1) and (2). - ANSWER- floor-mounted receptacles

In a dwelling, what is the minimum width of a wall space that requires a receptacle outlet? - ANSWER- 2 feet

In a house ___ receptacles should be installed along a 15-foot long kitchen countertop per the minimum requirements in the

NEC®. - ANSWER- 4

The plan view for the kitchen countertops in a house is shown in Figure 108.013. The fewest number of receptacles that can be installed along the 7′-9″ & 7′-1″ countertops is ___. -

ANSWER- 4

A 23-foot long hallway is shown above in Figure 108.020. If this hallway is in the Mayor's house, how many wall receptacles are required by the NEC®? - ANSWER- at least one

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 30, 2025
Description:

IEC YEAR 2 FINAL EXAM NEWEST 2024 -2025 ACTUAL EXAM COMPLETE 350 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ What is the maximum allowable voltage between conductor...

Get this document $30.00