- | P a g e
IEC YEAR 4 FINAL EXAM NEWEST 2024 -2025 ACTUAL
EXAM COMPLETE 350 QUESTIONS AND CORRECT
DETAILED ANSWERS (VERIFIED ANSWERS)
|ALREADY GRADED A+
No receptacle shall ever be permitted to be installed within ___ feet of the inside walls of a pool.
Select one:
- 20
- 18
- 6
- 15 - ANSWER- c. 6
No luminaires shall be installed in swimming pools for operation on supply circuits over ___ volts between conductors.
Select one:
- 150
- 30
- 300
- 50
- 130 - ANSWER- a. 150
- / 4
- | P a g e
A branch circuit is supplying a single hermetic refrigerant motor- compressor for an air conditioning unit. The hermetic refrigerant motor- compressor rated-load current is 18 amperes. If a 30-ampere fuse will not start the motor-compressor, the maximum rating of the branch- circuit short-circuit and ground-fault protective device may be increased to ___.
Select one:
- 45 amps
- 35 amps
- 50 amps
- 40 amps - ANSWER- d. 40 amps
Determine the minimum copper THHN conductor size required to connect a 15 KVAR, 480-volt, three-phase capacitor bank to a 50 hp, three-phase motor.
Select one:
- 10 AWG
- 14 AWG
- 12 AWG
- 8 AWG
- 6 AWG - ANSWER- a. 10 AWG
The wiring of an outdoor sign that is portable or mobile and is in a wet location shall be ___.
Select one: 2 / 4
- | P a g e
- protected by a 20-ampere overcurrent protective device
- provided with ground-fault circuit-interrupter protection for personnel
- provided with factory-installed ground-fault circuit-interrupter
- none of the these - ANSWER- c. provided with factory-installed
protection for personnel
ground-fault circuit-interrupter protection for personnel
The maximum number of 15-amp receptacles permitted on a freestanding office partition is ___.
Select one:
- 6
- 13
- 2
- 10 - ANSWER- b. 13
Conductors that supply one or more arc welders shall be protected by an overcurrent device rated or set at not more than ___% of the conductor ampacity.
Select one:
- 70
- 200
- 125
- 50
- 80 - ANSWER- b. 200
- / 4
- | P a g e
For PV systems, conductor ampacities must be correct if installed in ambient temperatures exceeding ___°F.
Select one:
- 83
- 78
- 71
- 86 - ANSWER- d. 86
A disconnecting means shall be provided for all ungrounded conductors derived from a stationary battery system with a voltage over ___ volts dc.
Select one:
- 100
- 60
- 50
- 30 - ANSWER- b. 60
Automatic transfer switches (ATS) for emergency systems shall be electrically operated and ___ held.
Select one:
- mechanically
- manually
- automatically
- pneumatically
- / 4