A branch circuit is supplying a single hermetic refrigerant motor-compressor for an air conditioning unit. The hermetic refrigerant motor-compressor rated-load current is 18 amperes. If a 30-ampere fuse will not start the motor-compressor, the maximum rating of the branch-circuit short-circuit and ground-fault protective device may be increased to ___.

Select one:

  • 45 amps
  • 35 amps
  • 50 amps
  • 40 amps - ANSWER✅✅d. 40 amps
  • Determine the minimum copper THHN conductor size required to connect a 15 KVAR, 480-volt, three-phase capacitor bank to a 50 hp, three-phase motor.

Select one:

  • 10 AWG
  • 14 AWG
  • 12 AWG
  • 8 AWG
  • 6 AWG - ANSWER✅✅a. 10 AWG
  • The wiring of an outdoor sign that is portable or mobile and is in a wet location shall be ___.

Select one:

  • protected by a 20-ampere overcurrent protective device
  • provided with ground-fault circuit-interrupter protection for personnel
  • provided with factory-installed ground-fault circuit-interrupter protection for personnel
  • none of the these - ANSWER✅✅c. provided with factory-installed ground-fault circuit-
  • interrupter protection for personnel The maximum number of 15-amp receptacles permitted on a freestanding office partition is

___. 1 / 3

  • | P a g e

Select one:

  • 6
  • 13
  • 2
  • 10 - ANSWER✅✅b. 13
  • Conductors that supply one or more arc welders shall be protected by an overcurrent device rated or set at not more than ___% of the conductor ampacity.

Select one:

  • 70
  • 200
  • 125
  • 50
  • 80 - ANSWER✅✅b. 200
  • For PV systems, conductor ampacities must be correct if installed in ambient temperatures exceeding ___°F.

Select one:

  • 83
  • 78
  • 71
  • 86 - ANSWER✅✅d. 86
  • A disconnecting means shall be provided for all ungrounded conductors derived from a stationary battery system with a voltage over ___ volts dc.

Select one:

  • 100
  • 60
  • 50
  • 30 - ANSWER✅✅b. 60 2 / 3
  • | P a g e

Automatic transfer switches (ATS) for emergency systems shall be electrically operated and ___ held.

Select one:

  • mechanically
  • manually
  • automatically
  • pneumatically
  • electrically - ANSWER✅✅a. mechanically
  • The optional standby system wiring ___ be permitted to occupy the same raceways, cables, boxes, and cabinets with other general wiring.

Select one:

  • shall
  • shall not - ANSWER✅✅a. shall
  • When emergency system power generators are out of service for major maintenance or repair, ___ shall be available.

Select one:

  • utility power
  • a temporary or portable alternate source
  • a wind powered source
  • a solar powered source
  • any of these - ANSWER✅✅b. a temporary or portable alternate source
  • A typical standby system ATS ___.

Select one:

  • transfers the electrical load to the generator when the normal source fails
  • disconnects the normal power source connections when the normal power source fails
  • signals the generator to stop when the normal power source is restored
  • transfers the load back to the normal power source when the normal source is restored
  • all of these - ANSWER✅✅e. all of these
  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 29, 2025
Description:

IEC YEAR 4 FINAL EXAM STUDY WITH CORRECT ANSWERS 2024 LATEST UPDATE. A branch circuit is supplying a single hermetic refrigerant motor-compressor for an air conditioning unit. The hermetic refriger...

Get this document $30.00