Level 1 Module 11 Residential Electrical Services Exam 2023 Questions and Answers Which of that following locations at dwelling units require GFCI protection?

  • Receptacles within garages
  • Which type of cable with a corrugated sheath has a maximum bend raduis of 7 times the cable diameter?

  • Type MC
  • Which of the following circuits require a minimum of 20A of overcurrent protection?

  • Residential small appliance branch circuits
  • According to the NEC, which of the following is required for the small appliance loads in each kitchen area?

  • Two 120V, 20A small appliance branch circuits
  • According to NEC Section 220.53, loads for which of the following appliances shall be permissible to apply a demand factor of 75%?

  • Fixed appliances
  • The NEC allows the load calculation for the ground neutral conductor supplying electric ranges and dryers to have a demand factor of ______.

  • 70%
  • Which of the following is required to carry the lighting load for the residence in the figure above?

  • Two 15A circuits
  • How many square feet of livable space are in the home in figure above?

  • 1,200
  • Which of the following is the minimum NEC lighting load requirement for the home in the figure above?

  • 3,600VA
  • Which of the following is an NEC-approved grounding electrode?

  • Metal underground water pipe in direct contact with the earth for 10 feet
  • The minimum clearance of service drop conductors over a residential driveway is reduced to 12 feet when the voltage is limited to ________.

  • 300V to ground
  • The section of the NEC that lists the requirements for installing service disconnecting means is ______.

  • NEC Section 230.70
  • Romex is a trade name for _____.

  • Type NM cable
  • Cables routed through bored holes in framing members must maintain a distance from the nearest edge of not less than ______.

  • 1-1/4 inches
  • Which of the following must be supported at intervals of 6 feet or less?

  • Type MC cable
  • Which of the following will detect a current imbalance as low as 4 miliamps?

  • A GFCI sensor
  • / 1

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 2, 2025
Description:

Level 1 Module 11 Residential Electrical Services Exam 2023 Questions and Answers Which of that following locations at dwelling units require GFCI protection? a. Receptacles within garages Which ty...

Get this document $30.00