MASSACHUSETTS OIL BURNER LICENSE NEWEST

2024 ACTUAL EXAM TEST BA NK 350 QUESTIONS AND

CORRECT DETAILED ANSWERS (VERIFIED

ANSWERS) |ALREADY GRADED A+

What must be done prior to installing an oil burner - ANSWER- One must get a permit before installing an oil burner

What are the four no heat call steps - ANSWER- #1Oil check#2 fuse breaker#3 emergency switch#4 power

What are the requirements for oil fuel vent pipes that terminate outside of the building - ANSWER- No openings within two feet of vent

What is the safety timing of a gas pilot ignition - ANSWER- 15 seconds or less

What must be done to install an additional fuel tank in a building that already has a tank holding 1320 gallons - ANSWER- They must have a firewall around them

What must be done with the bypass plug on a two pipe system and on a one pipe system - ANSWER- On a one pipe system. 1 / 4

the bypass plug must be removed .on a two pipe system the bypass must be installed.

What is a bypass plug - ANSWER- A 1/16 inch plug to convert

  • pipe to a 2 pipe system

What is a power burner - ANSWER- Anything that's not a vaporizing oil burner

Can a series 10 .3 wire thermostat be used with a 2-wire control?explain. - ANSWER- Yes by jumping out the ground

Can a series 80 dryer thermostat be wired into a 3-wire control - ANSWER- No

What is the greatest loss in a boiler - ANSWER- Heat loss through the chimney

How high on the wall should thermostat be installed - ANSWER- 5 feet from the ground

What must be checked while installing a Mercury bulb thermostat - ANSWER- Must be checked to be level 2 / 4

Why are low voltage thermostats use more than line voltage ones - ANSWER- Safety

What additional requirements are there for installing two or more tanks to a common discharge line - ANSWER- They must be on a common slab at the same height and secure to one another

  • oil burners have been installed in a large room which is of
  • tight construction and which must be kept closed at all times there is decidedly not enough combustion air for proper burner operation there burner sizes are 1.35 gallons per hour under these conditions what is the minimum free area of an opening connecting to the outdoors which must be provided - ANSWER- 567 inch by 2 inch vent going to outside

what is the maximum voltage allowed for an oil burner circuit - ANSWER- 150 volts

Is carbon monoxide a desirable element in flue gases - ANSWER- No

  • / 4

How much air is needed to burn a gallon of fuel oil and why - ANSWER- 14.4 plus 50% 192 feet cubed 154 CF to ensure enough oxygen

When visually adjusting the flame on an oil burner you should try to get - ANSWER- An orange flame with red Flame tips

Explain how a burner should be piped when the supply tank is located below the burner - ANSWER- 2. Pipe dual stage with a bypass plug

How should a stack switch be installed according to 527 CMR 4.00 - ANSWER- With a flexible conduit

Why should a stack switch not be rigidly mounted - ANSWER- So you can pull it out and check it

What are the purposes of a hot and cold contacts in stack

switches - ANSWER- Hot: as they heat up hot contacts close

.Cold: normally closed switches open when heat heats them up.

What is delayed ignition - ANSWER- Fuel introduced to the combustion chamber before ignition

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 30, 2025
Description:

MASSACHUSETTS OIL BURNER LICENSE NEWEST 2024 ACTUAL EXAM TEST BA NK 350 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ What must be done prior to installing an oil bur...

Get this document $30.00