MDCB: Mock Exam 2 Questions with 100%

Verified Correct Answers A patient receiving treatment to the head and neck region has experienced a skin reaction and mucositis at a total dose much lower than anticipated. The radiation oncologist requests an evaluation of the treatment. Which of the following steps should be taken?

  • recalculate the treatment plan
  • ensure that the depth dose, build-up region, wedge parameters, and other pertinent information
  • for the treatment unit are correct

  • review the treatment setup with the therapist
  • recalculate the monitor unit settings
  • all are correct - Correct Answer E

For megavoltage dosimetry, TLD can provide accuracy of:

  • plus/minus 20%
  • plus/minus 10%
  • plus/minus 3%
  • plus/minus 1% - Correct Answer C

With megavoltage film dosimetry, isodose curves can be measured to within:

  • plus/minus 10%
  • plus/minus 7% 1 / 4
  • plus/minus 3%
  • plus/minus 1% - Correct Answer C

In megavoltage therapy, typical use(s) of diodes is for:

  • patient dosimetry
  • beam scanning
  • quality assurance
  • all of the answers are correct - Correct Answer D

Which of the following is best suited for calibration of a megavoltage beam:

  • diode detector
  • thermoluminescence dosimetry
  • film
  • ionization chamber - Correct Answer D

The f-factor:

  • is the roentgen to cGy conversion factor
  • is greatest for high Z materials and low energy photons 2 / 4
  • is 0.873 in air
  • all of the answers are correct
  • none of the answers are correct - Correct Answer D
  • Clinical application of MLC include which of the following?

  • shaping of electron fields as a replacement for cerrobend blocks
  • dynamic field shaping as a function of patient respiration
  • field shaping without penumbra
  • modulating beam intensity - Correct Answer D

The 104% isodose lines at the four corners of the target shown are due to the:

  • inhomogeneity of the femur
  • scatter from the femur
  • horns of the beams
  • weights of the lateral beams
  • use of a wrong algorithm - Correct Answer C

Exposure is:

  • the amount of energy in Joules/kg transferred from a photon beam to a material 3 / 4
  • only defined for photons and charged particles below 3 MeV
  • the charge liberated by photons in a given mass of air
  • the absorbed dose multiplied by the quality factor
  • None of the answers - Correct Answer C

The quantity that an ionization chamber actually measures is:

  • roentgen
  • gray
  • charge
  • kerma
  • voltage - Correct Answer C

Geiger counters:

  • are sensitive enough to detect individual photons or particles
  • are less sensitive than ionization chambers
  • are used to calibrate linac output
  • operate on the principle of scintillation - Correct Answer A
  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Sep 5, 2025
Description:

MDCB: Mock Exam 2 Questions with 100% Verified Correct Answers A patient receiving treatment to the head and neck region has experienced a skin reaction and mucositis at a total dose much lower tha...

Get this document $30.00