MDCB Practice Questions With 100% Verified Correct Answers A patient is to receive 55 Gy to a tumor in the mediastinum. In order to meet the acceptable dose
limits for the spinal cord, you could:
- use high energy photon beams to decrease the entrance dose.
- block the spinal cord out of all treatment fields after 40 Gy is delivered.
- use a BID treatment technique to achieve greater repair time for the normal tissue cells.
- utilize a 3DCRT beam arrangement including oblique beam angles. - Correct Answer d. utilize a
- half-life 86.4 days.
- has life-long radiation protection issues.
- energy of 0.412 MeV.
- decays exclusively by electron capture. - Correct Answer d. decays exclusively by electron capture.
- a change in the spectral energy distribution within the cavity.
- an increased primary photon transmission through the cavity.
- an enhanced absorption of dose in and beyond the cavity.
- a partial gain of electronic equilibrium at the cavity interface. - Correct Answer b. an increased
- 800cGy in 1 fraction.
- 2000cGy in 5 fractions.
- 3000cGy in 10 fractions.
- 3750cGy in 15 fractions. - Correct Answer a. 800cGy in 1 fraction.
3DCRT beam arrangement including oblique beam angles.Which of the following statements are true for Iodine-125?
The most significant effect(s) of an air cavity in a megavoltage beam treatment is:
primary photon transmission through the cavity.For patients with limited life expectancy the common dose fractionation for cord compression is:
Mayneord F factor corrects PDD for:
- heterogeneity.
- scatter. 1 / 2
- Inverse square.
- exponential attenuation. - Correct Answer b. Inverse square- does not correct for scatter
- +- 1%
- +- 2%
- +- 3%
- +- 5% - Correct Answer b. +- 2%
For quality assurance of brachytherapy treatment planning computers, the dose rates should agree with published data tables to which of the following degrees?
The expected accuracy of treatment planning systems that perform brachytherapy dose calculations
should be within: a. +/- 3%
- +/- 5%
- +/- 7%
- +/- 10% - Correct Answer b. +/- 5%
- 40 - 60 %
- 60 - 90 %
- 90 - 100 %
- > 100 % - Correct Answer c. 90 - 100 %
- Relative output factor
- Back scatter factor
- Percent depth dose
- Tissue maximum ratio - Correct Answer A. Relative output factor
- prophase
- metaphase
- / 2
With LINAC based SBRT/SABR and a plan that has a 100% maximum IDL, what is the typical range of prescription isodose line covering the PTV?
The ratio of the dose rate of a given field size to the dose rate of the reference field size is:
During which stage of mitosis do the chromosomes align across the equator of the spindle fibers?