MDCB Practice Questions With 100% Verified Correct Answers A patient is to receive 55 Gy to a tumor in the mediastinum. In order to meet the acceptable dose

limits for the spinal cord, you could:

  • use high energy photon beams to decrease the entrance dose.
  • block the spinal cord out of all treatment fields after 40 Gy is delivered.
  • use a BID treatment technique to achieve greater repair time for the normal tissue cells.
  • utilize a 3DCRT beam arrangement including oblique beam angles. - Correct Answer d. utilize a
  • 3DCRT beam arrangement including oblique beam angles.Which of the following statements are true for Iodine-125?

  • half-life 86.4 days.
  • has life-long radiation protection issues.
  • energy of 0.412 MeV.
  • decays exclusively by electron capture. - Correct Answer d. decays exclusively by electron capture.
  • The most significant effect(s) of an air cavity in a megavoltage beam treatment is:

  • a change in the spectral energy distribution within the cavity.
  • an increased primary photon transmission through the cavity.
  • an enhanced absorption of dose in and beyond the cavity.
  • a partial gain of electronic equilibrium at the cavity interface. - Correct Answer b. an increased
  • primary photon transmission through the cavity.For patients with limited life expectancy the common dose fractionation for cord compression is:

  • 800cGy in 1 fraction.
  • 2000cGy in 5 fractions.
  • 3000cGy in 10 fractions.
  • 3750cGy in 15 fractions. - Correct Answer a. 800cGy in 1 fraction.

Mayneord F factor corrects PDD for:

  • heterogeneity.
  • scatter. 1 / 2
  • Inverse square.
  • exponential attenuation. - Correct Answer b. Inverse square- does not correct for scatter
  • For quality assurance of brachytherapy treatment planning computers, the dose rates should agree with published data tables to which of the following degrees?

  • +- 1%
  • +- 2%
  • +- 3%
  • +- 5% - Correct Answer b. +- 2%
  • The expected accuracy of treatment planning systems that perform brachytherapy dose calculations

should be within: a. +/- 3%

  • +/- 5%
  • +/- 7%
  • +/- 10% - Correct Answer b. +/- 5%
  • With LINAC based SBRT/SABR and a plan that has a 100% maximum IDL, what is the typical range of prescription isodose line covering the PTV?

  • 40 - 60 %
  • 60 - 90 %
  • 90 - 100 %
  • > 100 % - Correct Answer c. 90 - 100 %
  • The ratio of the dose rate of a given field size to the dose rate of the reference field size is:

  • Relative output factor
  • Back scatter factor
  • Percent depth dose
  • Tissue maximum ratio - Correct Answer A. Relative output factor
  • During which stage of mitosis do the chromosomes align across the equator of the spindle fibers?

  • prophase
  • metaphase
  • / 2

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Sep 5, 2025
Description:

MDCB Practice Questions With 100% Verified Correct Answers A patient is to receive 55 Gy to a tumor in the mediastinum. In order to meet the acceptable dose limits for the spinal cord, you could: a...

Get this document $30.00