MRSO: Exam 2 Questions with Correct Answers
What is the name of the gradient coil used to produce sagittal and coronal images?
- Transverse coil
- Golay coil
- Maxwell coil
- Receiver coil - Correct Answers b. Golay coil ("saddle coil")
- elderly
- adult
- obese adult
- neonate - Correct Answers d. neonate
- Increase the TR
- Decrease receiving bandwidth
- Increase receiving bandwidth
- Use a receive only coil
- Increase field of view
- Increase flip angle - Correct Answers b, e
- Spatial magnetic gradient
- Gauss line
- RF energy 1 / 3
Which of the following is able to handle the most RF heating?
Which of the following techniques can be used to increase the echo spacing? Select all that apply.
Decreasing the receiving bandwidth will be lengthening the sample time. This may force us to increase our TE as well as the TR. Increasing the field of view will also allow for longer echo spacing.The differences in magnetic field strength as you approach the MRI unit is termed what?
- Gradient coils - Correct Answers a. Spatial magnetic gradient
- Conventional spin echo
- Fast spin echo
- Gradient echo
- EPI - Correct Answers d. EPI
- 0.5 gravity force
- 2 gravity force
- 0.25 gravity force
- 1 gravity force - Correct Answers d. 1 gravity force
- 4000 G/cm
- 4G/cm
- 40 G/cm
- 400 G/cm - Correct Answers d. 400 G/cm
Measured in dB/dx Which of the following produce the greatest chance for peripheral nerve stimulation?
A deflection of 45 degrees in a tested implant indicates that it deflects at a force equal to what?
4T/m is equal to what?
1T = 10,000 G
1m = 100 cm Therefore, 1 T/m=10,000G/100cm This means that 1 T/m=100 G/cm How do we calculate the maximal spatial gradient?
- dB/dx * B 2 / 3
- dB/dt * W/kg
- W/kg
- B - Correct Answers a. dB/dx * B
- ACR Blue Ribbon Panel on MR safety
- FDA
- OSHA
- EPA - Correct Answers a. ACR Blue Ribbon Panel on MR safety
- Less than blood
- Greater than blood
- Less than water
- Equal to blood - Correct Answers b. Greater than blood (and greater than water)
- We reduce patient heating
- We use a stronger time-varying gradient magnetic field
- We use a weak time-varying gradient magnetic field
- We increase the patient heating - Correct Answers c. We use a weak time-varying magnetic field.
- Bright
- / 3
What group issued the ACR white paper MRI safety?
Which of the following is true of a gad contrast osmolarity?
Which of the following is true if we increase the field of view from 200mm to 400mm?
Larger field of views will produce lower resolution exams. The size of the field of view is dependent on the frequency encoding gradient coil. When we increase the field of view, we decrease the amplitude of our gradient coil.When a T1 weighted image is taken of a vial of gad contrast, it will appear how?