NAB NHA Exam Compiled Cards Human Resources Leadership and Management Physical, Environmental, and Atmosphere Resident Care Management and Quality of Life Financial Management the physical plant - CORRECT ANSWER all designed, constructed, equipped, and maintained to protect health and safety of residents, personnel, public Life Safety Code (LSC) - CORRECT ANSWER Entire construction plan and materials meet LSC standards|||CMS requires unless have waiver or exception.CMS grants waivers on SNFs; states on NFs (NFPA) - CORRECT ANSWER National Fire Protection Association || established LSC 1 / 4
Purpose of LSC - CORRECT ANSWER to provide reasonable degree of safety from fire.Waivers for Life Safety Code - CORRECT ANSWER If CMS finds a state fire and safety code adequately protects residents and personnel thenLSC does not apply. OLder facilities may obtain a waiver if they are and have been in compliance with an older addition of LSC as specified by CMS.||Before a nursing home may be built it must present architectural plant to State Medicaid or designated agency that approves construction. All major renovations, such as additional beds, change in utilization of space, and so on must receive approval.The state provides guidelines on what must be a approved. Upkeep and repairs do not require prior approaval.Blue Prints - CORRECT ANSWER keep as-built plans available for surveyors who do LSC inspection as well as for repair persons who may need prints for big jobs.LSC and other standards - CORRECT ANSWER Building and contact standards are set by LSC, CMS, ANSI/ADAAG - (dependent on which the state chooses) and state and local codes. ||- for handicapped|-follow which on specific state requires (ANSI/ADAAG) 2 / 4
LSC and ANSI/ADAAG - CORRECT ANSWER LSC accepts both standards so they are essentially all LSC standards. Administrator does not need to know EVERY standard, but must keep a copy of the "LSC Handbook" as reference. The architect who designs the facility must know and incorporate all LSC and other standards, but it is advisable for the NHA to check his building to ensure compliance.LSC, ANSI/ADAAG, and CMS - CORRECT ANSWER **- building materials - fire-rate according to number of stories. 2 hour and 1 hour rating|**- sprinklers - new buildings have automatically activated by smoke/heat|- exits - no room more than 100 feet from exit. Lighted exit signs of specific size. |- walls extend continuously to roof deck of next floor. wall finish must meet flame-spread requirements ( have certificate of this)|- furnishings - curtains and carpet must meet fire rating|- rooms - CMS requirements - 4 residents to room MAX. 80 sq ft/resident (multi-resident room), 100 sq ft for single occupancy.requirement for rooms| - CORRECT ANSWER - direct access to corridor|- outside window (CMS) or door (LSC)|- privacy|- furnishing| separate bed, proper size and height| bedding appropriate to climate| individual closet space| bedside table| comfortable chair| enough overbid tables to meet needs of rsidents|- toilets (CMS, ANSI, ADA)|- bathing facilities (CMS)|- resident call system (CMS, LSC) 24/7 - back up system available|- temperature range (71-81 degree F) (three feet above floor), states set actual, A/C not required 3 / 4
Doors - CORRECT ANSWER All 44" or more in new construction (41.5 opening)|outside doors open egress.|no locks on resident door except staff has key (LSC)||Bathroom door 32" (ANSI/ADAAG)||Fire Doors with automatic hold- open devices required in corridors||(over bed tables not required for patient) corridors - CORRECT ANSWER no dead-ends (LSC)||8 feet wide (CMS) Floors - CORRECT ANSWER at or above ground level. (LSC) |Fire rating if carpeted. (LSC)|Non-slip bath/toilet (ANSI, LSC)|Asphalt tile best Fire alarms - CORRECT ANSWER flashing and audible. |connect with local fire dept, if possible|must have NFPA 71 certification of fire alarm service| smoke detectors - CORRECT ANSWER approved detectors requried
- / 4