NATE Exam Air Conditioning and Heat Pumps

Study Guides Aug 27, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

NATE Exam Air Conditioning and Heat Pumps Latest Update 2025-2026 100 Questions and 100% Verified Correct Answers Guaranteed A+

A 24-V transformer with a 40-VA rating can operate safely with a current of ____.

  • 6.0 mA
  • 960.0 mA
  • 0.6 A

d. 1.67 A -CORRECT ANSWER: d (1.67 A)

A cooling anticipator in the control circuit is connected in ____ with the ____ switch of the thermostat.

  • parallel, cooling
  • parallel, heating
  • series, cooling

d. series, heating -CORRECT ANSWER: a (parallel, cooling)

A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible capacity of a cooling-only system should be within ____% of this calculated value.

  • ±10%
  • +10%
  • +15%

d. +30% -CORRECT ANSWER: c (+15%) 1 / 3

A good fuse will yield a reading of ____ on an ohmmeter.

  • 0 Ω
  • less than 1 Ω
  • infinity
  • a value that rises quickly to 0 before falling slowly toward infinity -CORRECT

ANSWER: a (0 Ω)

A resistance reading of 0 Ω across a coil indicates that the coil is ____.

  • good
  • grounded
  • open

d. shorted -CORRECT ANSWER: d (shorted)

A resistance reading of infinity between the "R" terminal and the "S" terminal of a compressor motor indicates a(n) ____.

  • grounded motor winding
  • open motor winding
  • shorted motor winding

d. tripped internal overload -CORRECT ANSWER: b (open motor winding)

A small voltage reading across a closed set of contacts in an energized circuit indicates that the ____.

  • contacts are in good condition 2 / 3
  • contacts are pitted
  • motor capacitor is defective
  • wrong voltage is supplied to the unit -CORRECT ANSWER: b (contacts are pitted)

A system should be operated for at least ____ before heat measurements are taken.

  • 20 minutes
  • 30 minutes
  • 45 minutes

d. 1 hour -CORRECT ANSWER: a (20 minutes)

According to Ohm's Law, what will happen if voltage to a heater element is increased by 10%?

  • The Btuh output will increase by 5%
  • The current draw will decrease by 10%
  • The current draw will increase by 10%
  • The heater will overheat -CORRECT ANSWER: c (the current draw will increase by
  • 10%)

All safety switches must be ____.

  • connected in parallel with the control switch
  • connected in series with the control switch
  • normally closed limit switches

d. open at the same time in order to protect the load -CORRECT ANSWER: b

(connected in series with the control switch)

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 27, 2025
Description:

NATE Exam Air Conditioning and Heat Pumps Latest Update 2025-2026 100 Questions and 100% Verified Correct Answers Guaranteed A+ A 24-V transformer with a 40-VA rating can operate safely with a curr...

Get this document $30.00