NATIONAL FUEL GAS CODE EXAM

NEWEST 2025 ACTUAL EXAM COMPLETE

200 QUESTIONS AND CORRECT DETAILED

ANSWERS (VERIFIED ANSWERS) |ALREADY

GRADED A+

Where a minimum of 12 inches of cover cannot be provided, the pipe shall be installed in ____ or bridged (shielded). - ANSWER-conduit

The trench for gas piping shall be ___ so that the pipe has a firm, substantially continuous bearing on the bottom of the trench. - ANSWER-graded

Underground gas piping, where installed through the outer foundation or basement wall of a building, shall be encased in a ___ ___ or protected by and approved device or method. - ANSWER-protective sleeve

The space between the gas piping and the sleeve and between the sleeve and the wall shall be ___ to prevent entry of gas and water - ANSWER-sealed 1 / 4

  • | P a g e

Plastic pipping shall be installed ___, ___ only - ANSWER- outdoors, underground

Connections made between metallic and plastic piping ___ ___

made with fittings conforming to one of the following:

ASTM D 2513

ASTM F 1973

ASTM F 2509 - ANSWER-shall be

An electrically continuous corrosion resistant ___ ___ or tape shall be buried with the plastic pipe to facilitate locating, & __ end shall be brought above ground at a building wall or riser. - ANSWER-tracer wire, one

Piping installed aboveground shall be ___ ___ and located where it will be protected from physical damage. - ANSWER- securely supported

Where passing through an exterior wall, the piping shall also be protected from ___ by coating or wrapping with an inert material approved for such applications. - ANSWER-corrosion 2 / 4

  • | P a g e

The piping shall be ___ around its circumference at the point of the exterior penetration to prevent the entry of water, insects, and rodents. - ANSWER-sealed

Piping for other than dry gas conditions shall be sloped no less than ___ in 15 ft to prevent traps. - ANSWER-1/4 inch

Gas piping inside any building ___ ___ be installed in or through a clothes chute, chimney, or gas vent, dumb waiter, elevator shaft, or air duct, other than combustion air ducts - ANSWER-shall not

Piping ___ ___ supported with metal pipe hooks, metal pipe straps, metal band, metal brackets, metal hangers, or building structural components, suitable for the size of piping of adequate strength and quality, and located at intervals so as to prevent or damp out excessive vibration. - ANSWER-shall be

Gas piping installed on the roof surfaces shall be ___ above the roof surface and shall be supported in accordance with table 7.2.5.2 - ANSWER-elevated

  • / 4
  • | P a g e

Gas fittings installed in concealed locations shall be limited to

the following:

1)______

2)_____

3)_____ - ANSWER-1) Threaded elbows, tees, and couplings 2)Brazed fittings 3) Welded fittings

For other than dry gas conditions, a drip ___ ___ provided at any point in the line of pipe where condensate could collect. - ANSWER-shall be

All drips shall be installed only in such locations that they are ___ ___ to permit cleaning or emptying - ANSWER-readily accessible

A drip shall not be located where the condensate is likely to ___.

  • ANSWER-freeze

Each gas outlet, including a valve, shall be ___ gastight with a threaded plug or cap immediately after installation and shall be

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: CAREER EXAMS
Added: Aug 5, 2025
Description:

NATIONAL FUEL GAS CODE EXAM NEWEST 2025 ACTUAL EXAM COMPLETE 200 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ Where a minimum of 12 inches of cover cannot be provide...

Get this document $30.00