NFPA 10 EXAM NEWEST 2024-2025 ACTUAL EXAM

EXAM ELABORATIONS Aug 30, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

  • | P a g e

NFPA 10 EXAM NEWEST 2024-2025 ACTUAL EXAM

COMPLETE 130 QUESTIONS AND CORRECT

DETAILED ANSWERS ( VERIFIED ANSWERS )

|ALREADY GRADED A+

Cartridge operated water extinguishers shall not be removed from service - ANSWER- False

Fire extinguishers shall be located along normal paths of travel, including exits from areas. - ANSWER- True

It is ok for hand held portable fire extinguishers to be left sitting on the floor as long as it is properly marked with location signs.

  • ANSWER- False

Fire extinguishers weighing less than 40lbs shall be installed so that the top of the extinguishers is not more than 6 feet from the floor. - ANSWER- False

Fire extinguishers weighing more than 40lbs shall be installed so that the top of the extinguisher is no more than 3.5 feet from the floor. - ANSWER- True 1 / 3

  • | P a g e

In no case shall the clearance between the bottom of the extinguisher and the floor be less than 4 inches. - ANSWER- False

Labels that specifically relate to operation, classification, or warning information shall not be permitted on the front of the extinguisher. - ANSWER- False

Which of the following conditions may result in the condemning of a fire extinguisher during inspection. - ANSWER- All of the above.

High pressure cylinders and cartridges including nitrogen cylinders and cartridges used as an expellant for wheeled fire extinguisher shall not be hydrostatically tested every 5 years. - ANSWER- False

Carbon dioxide fire extinguishers shall be tested at 5/3 the service pressure as stamped into the cylinder. - ANSWER- True

AFFF and FFFP fire extingulshers can be protected against temperatures below 40° F by adding an antifreeze charge. - ANSWER- False 2 / 3

  • | P a g e

The use of a Carbon Dioxide fire extinguisher - ANSWER- Should not be used in confined spaces

Burning metals - ANSWER- Known as class D fires and may react violently to water and significantly increase hazards associated with burning metals.

Items that affect distribution of portable fire extinguishers are: -

ANSWER- All of the above.

Carbon Dioxide hose assemblies have a continuous metal braid that connects to both couplings to minimize the static shock hazard. - ANSWER- True

Hydrotest labels should be printed in black with a light blue background - ANSWER- False

Halon Extinguisher Recharge- if the extinguisher valve is removed for service, what is the recommended? - ANSWER- Purge extinguisher with nitrogen

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 30, 2025
Description:

NFPA 10 EXAM NEWEST 2024-2025 ACTUAL EXAM COMPLETE 130 QUESTIONS AND CORRECT DETAILED ANSWERS ( VERIFIED ANSWERS ) |ALREADY GRADED A+ Cartridge operated water extinguishers shall not be removed fro...

Get this document $30.00