Question: Consider a fire alarm system with signaling line

circuit which has 24 devices. All means of interconnecting equipment shall be monitored for integrity so that the occurrence of a single _______ condition is automatically indicated within 200 seconds?

Answer : Open

Question: What ANSI/UL Publication is the Standard for Smoke

Detectors for Fire Alarm Systems?

Answer : 268

Question: According to NFPA 72, section _____ of the record

of completion is used to note the input voltage?

Answer : 5.1.1

Question: Power Limited fire alarm circuit conductors shall be

separated by at least _____ inches from any Class 1 conductors?

Answer : 2

  • | P a g e

Question: The secondary power supply for in building fire

emergency voice/alarm communication system shall be capable of operating the system during a fire or other emergency condition for a period of _____ minutes at maximum connected load?

Answer : 15

Question: What ANSI/UL Publication is the Standard for Single

and Multiple Station Smoke Alarms?

Answer : 217

Question: Consider a 24 volt circuit with a resistance of 8 ohms.

What is the current?

Answer : 3 amperes

Question: According to NFPA 72, the system record of

inspection and testing has supervising station monitoring at section ______ of the documentation?

Answer : 6.6

Question: Consider a circuit that is 24 volts with a current of 3

amperes and a resistance of 8 ohms. What is the power?

Answer : 72 watts

  • | P a g e

Question: Fire alarm signals, supervisory signals and trouble

signals shall be ________?

Answer : Distinctive

Question: A smoke detector shall be sensitivity tested within

_______ years of the initial installation?

Answer : 1

Question: In corridors where more than _____ visible

notification appliances are in any field of view they shall be synchronized.

Answer : 2

Question: For the purposes of alarm annunciation each ______

of the building shall be considered as a separate zone?

Answer : Floor

Question: Prior to installing fire alarm system cabling, it is

noted that the wire run will penetrate a floor from the main level of the building to the 1st floor area. What type of fire alarm cable is best suited for this application?

Answer : FPLR

  • | P a g e

Question: Exposed fire alarm cabling PLFA, which is within 7'

AFF shall be supported at intervals not to exceed _____ inches?

Answer : 18

Question: What is the minimum size THHN conductor that must

be used for a 15 amp circuit breaker to the fire alarm control panel?

Answer : 14 AWG

Question: An acceptable power source for a power limited fire

alarm circuit is a listed _____ power supply?

Answer : PLFA

Question: EMT shall be securely fastened in place at least every

_____ feet?

Answer : 10

Question: Intermediate metal conduit shall supported at intervals

not exceeding _______ feet.

Answer : 10

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 4, 2025
Description:

NICET LEVEL 1 NEWEST 2025 ACTUAL EXAM COMPLETE 100 QUESTIONS AND CORRECT DETAILED ANSWER S (VERIFIED ANSWER S) |ALREADY GRADED A+ (BRAND NEW VERSION!) Question: Consider a fire alarm system with si...

Get this document $30.00