NMTCB Practice Exam - New book with Complete Solutions Latest Updated 2024 In which RP is Tc99m left in the valence state of +7
- sulfur colloid
- MAA
- MAG3
- sestamibi - Correct Answer A. Sulfur colloid
- the order should be changed to Sr89
- the tx should be delayed until the platelet ct is at least 60,000
- the tx should be delayed until the WBC is below 2400
- the Sm153 should be ordered - Correct Answer B. the tx should be delayed until the
- 83 mCi/ml
- 125 mCi/ml
- 167 mCi/ml
- 500 mCi/ml - Correct Answer B. 125 mCi/ml
- true
- false - Correct Answer B. false
- the ability to match perfusion and vent positioning
- the ability to detect delayed washout
- the ability to perform the exam at the patient's bedside
- the ability to perform perfusion before ventilation without increasing the dose given for
a tech receives a request for a patient to receive Sm153 for palliation of pain from bone mets. the patient has a WBC count of 3500 and 40000 platelets. what should happen next?
platelet ct is at least 60,000 a SC kit requires the addition of 1-3 ml containing no more than 500mCi of TcO4-. in addition, 1.5 ml of solution A must be added before boiling, and 1.5 ml of Solution B must be added after cooling. If the kit is correctly prepared, what is the max concentration of Tc99m it could contain?
max. 1 ml TcO4- containing 500 mCi 500/(1.5+1.5+1) = 125 mCi/ml A hine-duley phantom is useful for testing the spatial resolution and spatial linearity with only one image.
the advantage of a lung ventilation scan performed with Xenon is
the vent study - Correct Answer B. the ability to detect delayed washout A diphosphonate kit contian 180 mCi of Tc99m in 30 ml when it is prepared at 8am.Immediately, a 20 mCi dose is withdrawn for a bone scan. if the patient arrives late at 9:30 and half the volume is accidentally discharged, how much volume from the kit must 1 / 2
now be added to the syringe to correct the dose to 20 mCi? (no other doses have been withdrawn meanwhile, and the decay factor for 1.5 hrs is 0.841)
- 1.5 ml
- 2.0 ml
- 2.3 ml
- 2.5 ml
- 2.7 ml - Correct Answer C. 2.3 mL
lots of math, sorry :(
a WBS bone scan film shows a good posterior image, but the anterior view appears diffuse with greater soft tissue activity. what is the probable cause?
- wrong collimator used for anterior
- increased patient to detector distance on the ant relative to the post
- low tagging efficiency of the RP
- patient was not sufficiently hydrated
- none of the above - Correct Answer b. increased patient to detector distance on the
- disposable eating utensils
- plastic covering over the mattress
- covering the phone receiver with plastic
- collecting the patient's waste and storing until decayed to background - Correct
ant relative to the post Which of the following will not reduce the probability of contamination from perspiration and saliva of a therapy patient?
Answer d. collecting the patient's waste and storing until decayed to background
bone marrow imaging is performed using:
- MDP
- HDP
- sulfur colloid
- Gd153
- A and B - Correct Answer C. sulfur colloid
- rule out brain mets
- to detect low tagging efficiency
- to detect a R-L cardiac shunt
- to see if pulmonary emboli have traveled into the cerebral arteries - Correct Answer c.
why would an image of the brain be obtained during a lung perfusion scan using Tc99m MAA?
to detect a R-L cardiac shunt all of the following have an effect on the concentration of eluate obtained from a wet
generator except:
- time since last elution
- volume of saline added to the charging port
- / 2