OIL BURNER LICENCE FINAL TEST WITH

Questions & answers Sep 7, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

OIL BURNER LICENCE FINAL TEST WITH

VERIFIED QUESTIONS AND ANSWERS ||

ALREADY GRADED A+ | GUARANTEED PASS |

BRAND NEW!!!

The power venter shall be sized in accordance with the: - ANSWER- Maximum

input capacity of the appliance

Any oil-soaked combustion chamber may be cleared by what method? - ANSWER- There is no method of cleaning an oil-soaked chamber, it must be removed

What is the maximum allowable flame reaction time? - ANSWER- 3-seconds

Under 3 gallons per hour, what is the maximum allowable time for ignition trials? - ANSWER- 45-seconds

What is the best way to remove surface oil? - ANSWER- Skimming

What is a safety control? - ANSWER- Any control used to prevent unsafe operation of the controlled equipment

What is a draft booster? - ANSWER- Power operated fan installed in the chimney connector to increase natural draft

  • / 3

What is a "confined space?" - ANSWER- Any space whose volume is less than 50 cubic feet per 1000 BTU's of all fuel burning equipment

What is "installation?" - ANSWER- Complete and ready for operation of any oil- burning appliance

The minimum distance a power vent may terminate above the finish grade is? - ANSWER- One-foot

The minimum distance a power vent may terminate from a door, window or gravity air intake is? - ANSWER- 4-feet

When a separate power venter and hood are used, the power venter shall be

located: - ANSWER- As close to the hood as possible

In a forced warm air system, the return air duct size must never be less than ________ of the supply air duct size. - ANSWER- 80%

12 pounds of pressure on a hot water boiler will push water how far up a pipe? - ANSWER- 28 feet

For the correct operation of a hot water heating system, it is essential to provide

for: - ANSWER- - Proper air elimination

  • Proper pipe sizing
  • System water expansion

To prevent gravity circulation through the hydronic system when the boiler maintains water temperature, we need a: - ANSWER- Flow control valve 2 / 3

The fluid in a wet-kit CO2 tester is good for ____ tests - ANSWER- 200

The hole in the flue pipe for combustion testing should be: - ANSWER- As close

to the breech of the heating unit as possible

How many gallons of oil are allowed in unenclosed tanks at a residence? -

ANSWER- 1320

What is the power that runs through wiring? - ANSWER- 150 volts to ground

Does a brick/mason chimney need to be lined? - ANSWER- Yes

A device that uses electricity to perform useful work is a: - ANSWER- Load

An electrical circuit for an oil burner will contain: - ANSWER- - A conductor from the power source to the burner and back to the power source

  • Switches
  • Loads

In a series circuit there is only one: - ANSWER- Path for current through the loads

Oil heating systems should be: - ANSWER- Wired on their own separate circuit

The heat anticipator in a thermostat should be set to: - ANSWER- The amperage

draws of the control circuit

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Questions & answers
Added: Sep 7, 2025
Description:

OIL BURNER LICENCE FINAL TEST WITH VERIFIED QUESTIONS AND ANSWERS || ALREADY GRADED A+ | GUARANTEED PASS | BRAND NEW!!! The power venter shall be sized in accordance with the: - ANSWER- Maximum inp...

Get this document $30.00