OIL BURNER LICENSE EXAM AND PRACTICE

EXAM NEWEST 2024-2025 ACTUAL EXAM

COMPLETE 250 QUESTIONS AND CORRECT

DETAILED ANSWERS (VERIFIED ANSWERS)

|ALREADY GRADED A+

OIL BURNER LICENSE EXAM

If the vacuum reading is substantially above the calculated

reading, (with the burner running) the cause may be: -

CORRECT ANSWER --Plugged fuel filter -Kinked oil supply line -Check valve sticking

With most new flame retention burners, the motor speed is: -

CORRECT ANSWER -3400 rpm

To check for a proper nozzle line cut-off, the pressure gauge is

installed in the: - CORRECT ANSWER -Nozzle port

Fuel units are generally set at the factory at: - CORRECT

ANSWER-100 psi

  • / 4
  • | P a g e

The oil burner nozzle in a high pressure burner performs the

following functions: - CORRECT ANSWER --Atomizes the oil

-Provides a pattern of oil spray -Delivers a fixed amount of oil

The nozzle flow rate, spray angle and pattern are directly related

to: - CORRECT ANSWER --Tangential slots

-Swirl chamber -Orifice

Cold oil or high viscosity problems may be eliminated by: -

CORRECT ANSWER --Increasing the pump pressure and reducing the nozzle size -Installing a nozzle line pre-heater

The following conditions or elements affect choosing the correct

nozzle spray patterns: - CORRECT ANSWER --Air-oil mixing

design of the burner -Shape of the chamber

Which condition affects nozzle spray droplet size? - CORRECT ANSWER-Fuel pump pressure

  • / 4
  • | P a g e

To burn one pound of fuel oil, how many pounds of air does it take? - CORRECT ANSWER -14.4 lbs

A layer of soot 1/16" thick will increase fuel consumption by: -

CORRECT ANSWER -4%

When sizing a combustion chamber for a firing rate of 1.00 gph,

you should provide a minimum floor space of: - CORRECT

ANSWER-Between 80 to 100 square inches

The most common type of burner design today is the: -

CORRECT ANSWER -High pressure atomizing

Poor draft due to a faulty chimney may be improved by

installing a good: - CORRECT ANSWER -Draft inducer

The draft differential produced by chimneys is best measured

with a draft gauge in: - CORRECT ANSWER -Inches of water

column

The most important draft measurement to be taken on any oil-

fired unit is: - CORRECT ANSWER --The draft at the breach

-The draft over the fire

  • / 4
  • | P a g e

The proper location to install a draft inducer is: - CORRECT

ANSWER-In the flue pipe between the draft regulator and the chimney

Using combustion test instruments to measure the composition and temperature of the flue gas as they leave the heating unit

will indicate the: - CORRECT ANSWER -Steady state

efficiency

The holes that are provided in the flue pipe for combustion

testing must be: - CORRECT ANSWER -Between the heating

unit and the draft regulator

When using a pump type smoke tester, 10 full strokes are

necessary to: - CORRECT ANSWER -Draw the proper amount

of fluegas past the paper

The fluid in a CO2 tester is good for how many tests? - CORRECT ANSWER -For about 200 tests

In an electric circuit in order for the wattage to remain the same

if the voltage drops, the amperage must: - CORRECT

ANSWER-Increase

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Aug 30, 2025
Description:

OIL BURNER LICENSE EXAM AND PRACTICE EXAM NEWEST 2024-2025 ACTUAL EXAM COMPLETE 250 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ OIL BURNER LICENSE EXAM If the vacuu...

Get this document $30.00