PFT Study Guide - - hemoptysis - cardiovascular disease - catarac...

EXAM ELABORATIONS Sep 4, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

PFT Study Guide

Contraindications include: - ANSWER-- pneumothorax (untreated)

  • hemoptysis
  • cardiovascular disease
  • cataract removal surgery (ocular pressure)

Pulmonary function devices that collect and measure GAS volumes - ANSWER-- water sealed spirometer

  • bellows spirometer
  • dry-rolling-seal spirometer

Lung volumes - ANSWER-how much air your lungs can hold

Spirometry determines - ANSWER-how quickly you can move air in & out of your lungs

Diffusing capacity - ANSWER-how well your lungs add oxygen & remove carbon dioxide

Purpose of performing pulmonary function tests (PFTs) - ANSWER-- Functional *status* of the *lungs*

  • *How MUCH & how FAST GAS* can be moved into and out of the lungs
  • *Diffusion characteristics* of the alveolar-capillary membrane

*the tests can dx. lung diseases & measure the severity of the disease*

Parameters to establish normal values for PFTs - ANSWER--*G*ender -*H*eight -*R*ace

  • Age

What is the most important factor influencing lung size and predicted values? - ANSWER-*Height*

the taller the person, the larger are predicted lung volumes, flow rates, and diffusing capacity.

Lung volumes and flow rates are affected typically when the BMI is greater than: - ANSWER-*BMI>30*

as a person gains weight, lung volumes and flow rates do not changes until the person becomes obese (BMI>30)

  • / 2

The instrument used primarily in PFT - ANSWER-Spirometer (for measuring routine *flows* & *volumes*)

Standard equipment in a pulmonary function laboratory - ANSWER-- Spirometer

  • Gas analyzer
  • Body plethysmograph

What is the volume of air inhaled and exhaled during quiet breathing? - ANSWER-tidal volume (Vt)

Normal minute ventilation of an average person at rest - ANSWER-4 to 12 L/min (depending of the size of the pt.)

Why is proper coaching of the pt. during FVC maneuver extremely important? - ANSWER-*ERRONEOUS FVC* test results (most common)

Restrictive lung disorders reduce FVC by - ANSWER-shrinking the lung (decrease in lung size)

Obstructive lung disorders reduce FVC by - ANSWER-increase in RV (caused by air trapping)

If measured FVC is significantly smaller than SVC, what is occurring? - ANSWER-air trapping

What level of VC is associated with *increased risk of postoperative respiratory complications*? - ANSWER-<20 ml/kg (reduced VC)

What level of VC is associated with *increased risk of respiratory failure*? - ANSWER- <15 ml/kg

indicates that the ventilatory reserve is decreased enough to cause resp. failure

Total lung capacity (TLC) is a function of the persons - ANSWER-- *A*ge

  • *R*ace
  • _ *G*ender

  • *S*ize

*reported as the Measured volume and as % Predicted*

The body plethysmograph uses which gas law? - ANSWER-Boyles law

The closed system helium dilution method is used to measure - ANSWER-FRC

  • / 2

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Sep 4, 2025
Description:

PFT Study Guide Contraindications include: - ANSWER-- pneumothorax (untreated) - hemoptysis - cardiovascular disease - cataract removal surgery (ocular pressure) Pulmonary function devices that col...

Get this document $30.00