Pennsylvania (Philadelphia) Standard Journeyman Plumber - 250_PA_PH Contractor Exam
- What is the minimum slope required for a 3-inch horizontal drainage pipe according to
- 1/8 inch per foot
- 1/4 inch per foot [ANSWER]
- 3/8 inch per foot
- 1/2 inch per foot
the Philadelphia Plumbing Code?
Rationale: The code requires 1/4 inch per foot slope for 2 1/2" through 3" horizontal drainage piping to maintain proper flow velocity and prevent blockages.
2. The minimum size trap for a standard residential bathtub is:
- 1 inch
- 1 1/4 inch
- 1 1/2 inch [ANSWER]
- 2 inch
Rationale: Philadelphia and IPC standards require a 1 1/2 inch trap for bathtubs to handle expected flow rates.
- A plumbing vent must terminate at least how many feet above the roof and away from
- 6 inches
- 12 inches
- 24 inches [ANSWER]
- 36 inches
any operable window?
Rationale: Vents must extend at least 2 feet above the roof and must be located away from windows to prevent sewer gases from entering the building.
4. The maximum distance from a P-trap to its vent for a 2-inch pipe is:
- 2 feet
- 4 feet
- 5 feet [ANSWER]
- 6 feet 1 / 4
Rationale: Per code, a 2-inch trap arm can extend 5 feet to the vent before losing effectiveness.
- Which fitting is prohibited for use in drainage systems?
- Sanitary tee
- Wye
- Combination wye and eighth bend
- Double sanitary tee on horizontal [ANSWER]
Rationale: Double sanitary tees on horizontal planes create turbulence and clog potential; prohibited by code.
- The device that prevents non-potable water from entering the potable water supply
system is called:
- Air gap
- Vacuum breaker
- Double check valve
- Backflow preventer [ANSWER]
Rationale: Backflow preventers (including air gaps, vacuum breakers, and check valves) protect potable water supply integrity.
7. The minimum pressure required at the highest fixture in a building is:
- 5 psi
- 10 psi
- 15 psi [ANSWER]
- 20 psi
Rationale: Code requires 15 psi minimum at the highest fixture for proper operation.
8. A cleanout is required for every building drain at:
- Each 25 feet
- Every change of direction greater than 45° [ANSWER]
- Each 50 feet
- Only at the main building exit
- / 4
Rationale: Cleanouts are placed at changes greater than 45° and at intervals based on pipe size.
- What is the standard developed length for a 1/2-inch water pipe supplying one bathroom
- 25 feet
- 50 feet [ANSWER]
- 75 feet
- 100 feet
group?
Rationale: For design purposes, fixture unit load and developed length are calculated to size supply piping.
10. The minimum size water service pipe allowed is:
- 1/2 inch
- 3/4 inch
- 1 inch [ANSWER]
- 1 1/4 inch
Rationale: Philadelphia requires at least a 1-inch service pipe to ensure adequate supply.
- The type of joint used for cast iron soil pipe with a rubber gasket is called:
- Caulked joint
- Compression joint [ANSWER]
- Soldered joint
- Brazed joint
Rationale: Compression gaskets (rubber ring) create watertight joints in hub-and-spigot cast iron pipe.
- What type of pipe is commonly used for natural gas distribution inside buildings?
A. PVC
- Copper
- Black steel [ANSWER]
D. ABS
Rationale: Black steel is the approved material for gas distribution piping inside structures.
13. The minimum trap seal depth required by code is:
- 1 inch
- 2 inches [ANSWER] 3 / 4
- 3 inches
- 4 inches
Rationale: Trap seals must be at least 2 inches deep to prevent sewer gas escape.
- Which of the following is an indirect waste connection?
- Kitchen sink
- Commercial ice machine [ANSWER]
- Water closet
- Lavatory
Rationale: Ice machines, dishwashers, and similar appliances require indirect waste connections through an air gap.
- The maximum number of water closets allowed on a 3-inch horizontal branch is:
- 1
- 2
C. 3 [ANSWER]
- 4
Rationale: A 3-inch horizontal branch may serve up to 3 water closets under IPC sizing rules.
- The required minimum air gap for a sink faucet outlet above the flood rim is:
- 1 inch
- 1.5 inches
- 2 times the diameter of the outlet [ANSWER]
- 3 inches
Rationale: Air gaps must equal at least twice the diameter of the water outlet to prevent back siphonage.
- Which of the following is NOT an acceptable method for joining copper tubing?
- Flared joint
- Compression fitting
- Threaded joint [ANSWER]
- Soldered joint
- / 4
Rationale: Copper tubing is not typically threaded; threading weakens the pipe wall.