Pennsylvania (Philadelphia) Standard Journeyman Plumber - 250_PA_PH Contractor Exam Questions and Answers Best rated A+ Guaranteed Success Latest Update
1.
The minimum slope required for a 3-inch horizontal drainage pipe is:
- 1/8 inch per foot
- 1/4 inch per foot [ANSWER]
- 3/8 inch per foot
- 1/2 inch per foot
Rationale: Per code, drainage pipes 3 inches or smaller must slope at least 1/4 inch per foot to maintain velocity for self-cleaning. Larger pipes (≥4") may use 1/8 inch per foot.
2.What type of pipe is not permitted for use in a water distribution system in Philadelphia?
- Copper (Type L)
B. CPVC
C. PEX
- Galvanized steel [ANSWER]
Rationale: Galvanized steel is prohibited due to corrosion and scaling. Copper, CPVC, and PEX are approved for water distribution under current codes.
3.
A cleanout must be installed:
- At the base of every stack
- At each change of direction greater than 45° in building drains
- Every 100 feet in horizontal drainage piping
- All of the above [ANSWER]
Rationale: Code requires cleanouts at stack bases, directional changes, and at intervals depending on pipe size. 1 / 4
4.
The maximum developed length of a 1½-inch trap arm without a vent is:
- 2 feet
- 3 feet
- 3 feet 6 inches [ANSWER]
- 5 feet
Rationale: Trap arms have strict limits to prevent siphoning. A 1½-inch trap arm is limited to 3'6".
5.
The fixture unit value assigned to a private bathtub is:
- 1
B. 2 [ANSWER]
- 3
- 4
Rationale: Per the plumbing fixture unit table, bathtubs are 2 fixture units in residential applications.
6.
A water closet with a flush tank is rated at:
- 2 fixture units
- 3 fixture units
- 2.5 fixture units [ANSWER]
- 4 fixture units
Rationale: Flush-tank toilets are generally rated at 2.5 fixture units under code.
7.
The minimum size vent serving a water closet is:
- 1 inch
- 1¼ inch 2 / 4
- 1½ inch [ANSWER]
- 2 inch
Rationale: Minimum vent size for a single WC is 1½". For multiple fixtures or longer runs, 2" may be required.
8.What is the maximum distance between a trap and its vent for a 2-inch trap arm?
- 3 feet
- 4 feet
- 5 feet [ANSWER]
- 6 feet
Rationale: Trap arm length is based on diameter; 2" trap arms can extend up to 5 feet before venting is required.
9.
A sump pump discharge must terminate:
- Into a floor drain
- Directly into a sanitary sewer
- To an approved discharge point with an air gap [ANSWER]
- Into a storm drain
Rationale: Discharge must prevent cross-connection and backflow; an air gap is required.
10.The minimum burial depth for underground water service piping in Philadelphia is:
- 12 inches
- 18 inches
- 36 inches [ANSWER]
- 48 inches
- / 4
Rationale: Water service pipes must be buried below the frost line, which in Philadelphia requires 36" depth.
11.Which type of fitting is prohibited in drainage piping?
- 45° elbow
- Long sweep elbow
- Short-radius 90° elbow [ANSWER]
- Wye branch
Rationale: Short-radius 90° elbows restrict flow and are not permitted in drainage systems.
12.
The minimum size building drain for a house with two bathrooms and 20 DFUs is:
- 2 inch
- 3 inch
- 4 inch [ANSWER]
- 6 inch
Rationale: Residential building drains are typically 4 inches minimum when serving more than one bathroom group.
13.
The air test for a drainage system requires:
- 5 psi for 5 minutes
- 10 psi for 10 minutes
- 5 psi for 15 minutes [ANSWER]
- 10 psi for 15 minutes
Rationale: Code requires a 5 psi air pressure test for a minimum of 15 minutes with no pressure drop.
14.The maximum spacing of supports for horizontal copper tubing (Type L) 1 inch in diameter is:
- 4 feet
- 6 feet [ANSWER]
- 8 feet
- 10 feet
- / 4